CPU, heat sink, and fan combinations
4 x 2.5'' models
CPU group | Config. | Heat sink | Fan |
Z/X | All configurations | Performance | Performance |
8 x 2.5''/4 x 3.5'' models
CPU group | Config. | Heat sink | Fan |
C | Non Mellanox ConnextX-6 NIC | Aluminum | Standard |
All other configurations | Aluminum | Performance | |
B | Non Mellanox ConnextX-6 NIC | Aluminum | Standard |
All other configurations | Aluminum | Performance | |
A | All configurations | Standard | Performance |
D | All configurations | Performance | Performance |
10 x 2.5'' models
CPU group | Config. | Heat sink | Fan |
C | Non Mellanox ConnextX-6 NIC | Aluminum | Standard |
All other configurations | Aluminum | Performance | |
B | All configurations | Aluminum | Performance |
A | All configurations | Standard | Performance |
D | All configurations | Performance | Performance |
Note
One CPU requires 6 fans (slot 1–6) and 2 fan dummies(7–8); two CPUs require 8 fans(slot 1–8).
If there is an OCP 3.0 Ethernet adapter installed, when the system is powered off but still plugged in to AC power, fans 5 and fan 6 will continue to spin at a much lower speed. This is the system design to provide proper cooling for the OCP 3.0 Ethernet adapter.
Give feedback