Skip to main content

CPU, heat sink, and fan combinations

For details about the CPU groups, see CPU.

4 x 2.5'' models

CPU groupConfig.Heat sinkFan
C/B/A/D/Z/XAll configurationsPerformancePerformance

8 x 2.5''/4 x 3.5'' models

CPU groupConfig.Heat sinkFan
C
  • Non-Mellanox ConnectX-6 NIC

  • Non-NVIDIA ConnectX-7 NIC

AluminumStandard/Performance
All other configurationsAluminumPerformance
B
  • Non-Mellanox ConnectX-6 NIC

  • Non-NVIDIA ConnectX-7 NIC

AluminumStandard/Performance
All other configurationsAluminumPerformance
AAll configurationsStandard/PerformancePerformance
DAll configurationsPerformancePerformance
Z/XAll configurationsPerformancePerformance

10 x 2.5'' models

CPU groupConfig.Heat sinkFan
C
  • Non-Mellanox ConnectX-6 NIC

  • Non-NVIDIA ConnectX-7 NIC

AluminumStandard/Performance
All other configurationsAluminumPerformance
BAll configurationsAluminumPerformance
AAll configurationsPerformancePerformance
DAll configurationsPerformancePerformance
Z/XAll configurationsPerformancePerformance
Note
  • One CPU requires 6 fans (slot 1–6) and 2 fan dummies (7–8), but you can also install 8 fans for one CPU; two CPUs require 8 fans (slot 1–8).

  • If there is an OCP 3.0 Ethernet adapter installed, when the system is powered off but still plugged in to AC power, fans 5 and fan 6 will continue to spin at a much lower speed. This is the system design to provide proper cooling for the OCP 3.0 Ethernet adapter.