Technical specifications
Summary of the technical specifications of server. Depending on the model, some features might not be available, or some specifications might not apply.
Processor |
---|
Supports multi-core Intel® Xeon® processors, with integrated memory controller and Intel Mesh UPI (Ultra Path Interconnect) topology.
For a list of supported processors, see Lenovo ServerProven website. |
Memory |
---|
See Memory module installation rules and order for detailed information about memory configuration and setup.
For a list of supported memory modules, see Lenovo ServerProven website. |
M.2 Drive |
---|
For a list of supported M.2 drives, see: Lenovo ServerProven website. |
Storage Expansion |
---|
Supported storage expansion varies by model.
|
Expansion slots |
---|
Supported expansion slots vary by model.
See PCIe slots and PCIe adapters for more information. |
Graphics processing unit (GPU) |
---|
The server supports GPU adapters installed in front PCIe slots with one of the following configuration:
For a list of supported GPU adapters, see: Lenovo ServerProven website. |
Integrated functions and I/O connectors |
---|
Note The maximum video resolution is 1920 x 1200 at 60 Hz. |
Network |
---|
|
RAID adapter |
---|
Note
|
Host bus adapter |
---|
Note
|
System fan |
---|
Note The redundant cooling by the fans in the server enables continued operation if one rotor of a fan fails. |
Electrical input and power policy | ||||||||
---|---|---|---|---|---|---|---|---|
Electrical input for power supply units Common Redundant Power Supply (CRPS) and CRPS Premium are supported as listed below: CAUTION
| ||||||||
Power supply | 100–127 V ac | 200–240 V ac | 240 V dc | -48 V dc | HVDC 240–380 V dc | HVAC 200–277 V ac | CRPS | CRPS Premium |
800-watt 80 PLUS Platinum | √ | √ | √ | √ | ||||
1300-watt 80 PLUS Platinum | √ | √ | √ | √ | ||||
1300-watt -48 V dc | √ | √ | ||||||
1300-watt HVAC/HVDC 80 PLUS Platinum | √ | √ | √ | |||||
2700-watt 80 PLUS Platinum | √ | √ | √ | |||||
800-watt 80 PLUS Titanium | √ | √ | √ | √ | √ | |||
1300-watt 80 PLUS Titanium | √ | √ | √ | √ | √ | |||
2000-watt 80 PLUS Titanium | √ | √ | √ | |||||
2700-watt 80 PLUS Titanium | √ | √ | √ | |||||
3200-watt 80 PLUS Titanium | √ | √ | √ | |||||
Power policy for power supply units Following is one or two power supply units for redundancy or over-subscription (OVS) support: Note
| ||||||||
Type | Watts | Redundancy | OVS | |||||
CRPS Premium | 800-watt 80 PLUS Titanium | 1+0 | × | × | ||||
1+1 | √ | √ | ||||||
1300-watt 80 PLUS Titanium | 1+0 | × | × | |||||
1+1 | √ | √ | ||||||
1300-watt -48 V dc | 1+1 | √ | √ | |||||
1300-watt HVAC/HVDC 80 PLUS Platinum | 1+1 | √ | √ | |||||
2000-watt 80 PLUS Titanium | 1+1 | √ | √ | |||||
2700-watt 80 PLUS Titanium | 1+1 | √ | √ | |||||
3200-watt 80 PLUS Titanium | 1+1 | √ | √ | |||||
CRPS | 800-watt 80 PLUS Platinum | 1+1 | √ | × | ||||
800-watt 80 PLUS Titanium | 1+1 | √ | × | |||||
1300-watt 80 PLUS Platinum | 1+1 | √ | × | |||||
1300-watt 80 PLUS Titanium | 1+1 | √ | × | |||||
2700-watt 80 PLUS Platinum | 1+1 | √ | × |