LEDs on the firmware and RoT security module
The following illustrations show the light-emitting diodes (LEDs) on the ThinkSystem V3 Firmware and Root of Trust Security Module (firmware and RoT security module).
1 AP0 LED (Green) | 2 AP1 LED (Green) | 3 Fatal Error LED (Amber) |
Scenario | AP0 LED | AP1 LED | Fatal Error LED | FPGA heartbeat LEDnote | XCC heartbeat LEDnote | Actions |
---|---|---|---|---|---|---|
RoT security module fatal firmware failure | Off | Off | On | N/A | N/A | Replace the firmware and RoT security module. |
Blink | N/A | On | N/A | N/A | Replace the firmware and RoT security module. | |
Blink | N/A | On | On | N/A | Replace the firmware and RoT security module. | |
No system power (FPGA heartbeat LED off) | Off | Off | Off | Off | Off | If the AC power is on, but the system board assembly does not have power, then:
|
XCC firmware recoverable error | Blink | N/A | Off | N/A | N/A | Information only. No action is required. |
XCC firmware is recovered from error | Blink | N/A | Off | N/A | N/A | Information only. No action is required. |
UEFI firmware authentication failure | N/A | Blink | Off | N/A | N/A | Information only. No action is required. |
UEFI firmware is recovered from authentication failure | N/A | On | Off | N/A | N/A | Information only. No action is required. |
System is OK (FPGA heartbeat LED is On) | On | On | Off | On | On | Information only. No action is required. |
For locations of the FPGA LED and XCC heartbeat LED, see