Baies d'unité avant 16 x 2,5 pouces (8 SAS + 8 AnyBay)
Cette section fournit des informations sur le cheminement des câbles pour le modèle de serveur doté de baies d’unité avant 16 x 2,5 pouces (8 SAS + 8 AnyBay).
Configuration | Storage controller | |
Qty. | Type | |
Config. 1 | 2 | SFF 8i RAID/HBA |
Config. 2 | 1 | SFF 16i RAID/HBA |
Config. 3 | 1 | CFF 16i RAID/HBA |
Config. 4 | 1 | SFF 32i RAID |
Configuration 1 – 4:
BP 1 + BP 2: 8 x 2.5'' SAS/SATA BP + 8 x 2.5'' AnyBay BP
SFF 8i RAID/HBA
SFF 16i RAID/HBA
Config. | Front BP | System board | Storage controller | |
SFF 8i RAID/HBA | SFF 16i RAID/HBA | |||
1 | BP 1: SAS | Gen 4: C 0 Gen3: C 0, C 1 | ||
BP 2: SAS | Gen 4: C 0 Gen3: C 0, C 1 | |||
BP 2: NVMe 0–1 | PCIe 1, PCIe 2 | |||
BP 2: NVMe 2–3 | PCIe 3 | |||
BP 2: NVMe 4–5 | PCIe 7 | |||
BP 2: NVMe 6–7 | PCIe 8 | |||
2 | BP 1: SAS | Gen 4: C 0 Gen3: C 0, C 1 | ||
BP 2: SAS | Gen 4: C 1 Gen3: C 2, C 3 | |||
BP 2: NVMe 0–1 | PCIe 1, PCIe 2 | |||
BP 2: NVMe 2–3 | PCIe 3 | |||
BP 2: NVMe 4–5 | PCIe 7 | |||
BP 2: NVMe 6–7 | PCIe 8 |
BP 1 + BP 2: 8 x 2.5'' SAS/SATA BP + 8 x 2.5'' AnyBay BP
CFF 16i RAID/HBA
SFF 32i RAID/HBA
Config. | Front BP | System board | Storage controller | |
CFF 16i RAID/HBA | SFF 32i RAID/HBA | |||
3 | BP 1: SAS | C 0, C 1 | ||
BP 2: SAS | C 2, C 3 | |||
BP 2: NVMe 0–1 | PCIe 1, PCIe 2 | |||
BP 2: NVMe 2–3 | PCIe 3 | |||
BP 2: NVMe 4–5 | PCIe 7 | |||
BP 2: NVMe 6–7 | PCIe 8 | |||
4 | BP 1: SAS | C 0 | ||
BP 2: SAS | C 1 | |||
BP 2: NVMe 0–1 | PCIe 1, PCIe 2 | |||
BP 2: NVMe 2–3 | PCIe 3 | |||
BP 2: NVMe 4–5 | PCIe 7 | |||
BP 2: NVMe 6–7 | PCIe 8 |
Exemple
Figure 1. Configuration 1
Envoyer des commentaires