24 x 2.5 英寸正面硬盘插槽(16 x SAS/SATA + 8 x AnyBay)
本节提供配备 24 x 2.5 英寸正面硬盘插槽(16 x SAS/SATA + 8 x AnyBay)的服务器型号的线缆布放信息。
| Configuration | Rear BP | Storage controller | ||
| Qty. | Type | Qty. | Type | |
| Config. 1 | 2 | CFF 16i RAID/HBA + CFF 48P RAID Expander | ||
| Config. 2 | 2 | SFF 8i RAID/HBA +CFF 48P RAID Expander | ||
| Config. 3 | 3 | SFF 8i RAID/HBA | ||
| Config. 4 | 1 | SFF 32i/24i RAID | ||
| Config. 5 | 1 | Rear: 4 x 2.5'' SAS/SATA | 2 | CFF 16i RAID/HBA + CFF 48P RAID Expander |
| Config. 6 | 1 | Rear: 4 x 2.5'' SAS/SATA | 2 | SFF 8i RAID/HBA + CFF 48P RAID Expander |
| Config. 7 | 1 | Rear: 4 x 2.5'' SAS/SATA | 3 | SFF 8i RAID/HBA |
| Config. 8 | 1 | Rear: 4 x 2.5'' SAS/SATA | 1 | SFF 32i RAID |
请根据您的服务器配置参阅以下部分之一以获取线缆布放信息。
Configuration 1 – 4:
BP 1 + BP 2 + BP 3: 8 x 2.5'' SAS/SATA BP + 8 x 2.5'' SAS/SATA BP + 8 x 2.5'' AnyBay BP
| Config. | Front BP | System board | Storage controller | ||
| CFF 48P RAID Expander | CFF 16i RAID/HBA | SFF 8i RAID/HBA | |||
| 1 | BP 1: SAS | C0 | |||
| BP 2: SAS | C1 | ||||
| BP 3: SAS | C2 | ||||
| RAID/HBA | C0, C1 | ||||
| PCIe 6 | MB | ||||
| BP 3: NVMe 0–1 | PCIe 1, PCIe 2 | ||||
| BP 3: NVMe 2–3 | PCIe 3 | ||||
| BP 3: NVMe 4–5 | PCIe 7 | ||||
| BP3: NVMe 6–7 | PCIe 8 | ||||
| 2 | BP 1: SAS | C0 | |||
| BP 2: SAS | C1 | ||||
| BP 3: SAS | C2 | ||||
| RAID/HBA | Gen 4: C0 Gen3: C0, C1 | ||||
| BP 3: NVMe 0–1 | PCIe 1, PCIe 2 | ||||
| BP 3: NVMe 2–3 | PCIe 3 | ||||
| BP 3: NVMe 4–5 | PCIe 7 | ||||
| BP3: NVMe 6–7 | PCIe 8 | ||||
| Config. | Front BP | System board | Storage controller | |
| SFF 8i RAID/HBA | SFF 32i/24i RAID | |||
| 3 | BP 1: SAS | Gen 4: C0 Gen3: C0, C1 | ||
| BP 2: SAS | Gen 4: C0 Gen3: C0, C1 | |||
| BP 3: SAS | Gen 4: C0 Gen3: C0, C1 | |||
| BP 3: NVMe 0–1 | PCIe 1, PCIe 2 | |||
| BP 3: NVMe 2–3 | PCIe 3 | |||
| BP 3: NVMe 4–5 | PCIe 7 | |||
| BP3: NVMe 6–7 | PCIe 8 | |||
| 4 | BP 1: SAS | 32i: C0 24i: C0/C1 | ||
| BP 2: SAS | 32i: C1 24i: C2/C3 | |||
| BP 3: SAS | 32i: C2 24i: C4/C5 | |||
| BP 3: NVMe 0–1 | PCIe 1, PCIe 2 | |||
| BP 3: NVMe 2–3 | PCIe 3 | |||
| BP 3: NVMe 4–5 | PCIe 7 | |||
| BP3: NVMe 6–7 | PCIe 8 | |||
示例
图 1. Configuration 2


Configuration 5 – 8:
BP 1 + BP 2 + BP 3: 8 x 2.5'' SAS/SATA BP + 8 x 2.5'' SAS/SATA BP + 8 x 2.5'' AnyBay BP
BP 4: 4 x 2.5'' SAS/SATA BP
| Config. | Front BP | Rear BP | System board | Storage controller | ||
| CFF 48PRAID Expander | CFF 16i RAID/HBA | SFF 8i RAID/HBA | ||||
| 5 | BP 1: SAS | C0 | ||||
| BP 2: SAS | C1 | |||||
| BP 3: SAS | C2 | |||||
| RAID/HBA | C0/C2, C1/C3 | |||||
| PCIe 6 | MB | |||||
| BP 4: SAS | C3 | |||||
| BP 3: NVMe 0–1 | PCIe 1, PCIe 2 | |||||
| BP 3: NVMe 2–3 | PCIe 3 | |||||
| BP 3: NVMe 4–5 | PCIe 7 | |||||
| BP3: NVMe 6–7 | PCIe 8 | |||||
| 6 | BP 1: SAS | C0 | ||||
| BP 2: SAS | C1 | |||||
| BP 3: SAS | C2 | |||||
| BP 4: SAS | C3 | |||||
| RAID/HBA | Gen 4: C0 Gen3: C0, C1 | |||||
| BP 3: NVMe 0–1 | PCIe 1, PCIe 2 | |||||
| BP 3: NVMe 2–3 | PCIe 3 | |||||
| BP 3: NVMe 4–5 | PCIe 7 | |||||
| BP3: NVMe 6–7 | PCIe 8 | |||||
| Config. | Front BP | Rear BP | System board | Storage controller | |
| SFF 8i RAID/HBA | SFF 32i RAID | ||||
| 7 | BP 1: SAS | Slot 2: Gen 4: C0/C1 Gen3: C0 | |||
| BP 2: SAS | Slot 3: Gen 4: C0/C1 Gen3: C0 | ||||
| BP 3: SAS | Slot 4: Gen 4: C0/C2 Gen3: C0/C1 | ||||
| BP 4: SAS | Slot 5: C0 | ||||
| BP 3: NVMe 0–1 | PCIe 1, PCIe 2 | ||||
| BP 3: NVMe 2–3 | PCIe 3 | ||||
| BP 3: NVMe 4–5 | PCIe 7 | ||||
| BP3: NVMe 6–7 | PCIe 8 | ||||
| 8 | BP 1: SAS | C0 | |||
| BP 2: SAS | C1 | ||||
| BP 3: SAS | C2 | ||||
| BP 4: SAS | C3 | ||||
| BP 3: NVMe 0–1 | PCIe 1, PCIe 2 | ||||
| BP 3: NVMe 2–3 | PCIe 3 | ||||
| BP 3: NVMe 4–5 | PCIe 7 | ||||
| BP3: NVMe 6–7 | PCIe 8 | ||||
示例
图 2. Configuration 5


提供反馈