Skip to main content

FQXSPPW0061M : Sensor [SensorElementName] has transitioned to critical from a less severe state.

Sensor [SensorElementName] has transitioned to critical from a less severe state.

This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.

Severity

Error

Alert Category

Critical - Power

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0522

SNMP Trap ID

4

Automatically Notify Support

No

User Action

  1. Please ensure the PSU wattage, PSU efficiency level and the power supply unit is supported for the system. Check power supply LEDs:
  2. If AC LED is not lit, check power cord and input voltage.
  3. If DC LED is not lit, remove and reinstall power supply.
  4. If error LED is lit, replace the power supply.
  5. If problem still exist, please send system event log to Lenovo service for further investigation.