Skip to main content

Specifications

The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.

Table 1. Specifications, Type 7X18 and 7X19.
SpecificationDescription
Dimension2U server
  • Height: 86.5 mm (3.4 inches)
  • Width:
    • With rack handles: 482 mm (19.0 inches)
    • Without rack handles: 444.6 mm (17.5 inches)
  • Depth: 763.7 mm (30.1 inches)
Note
The depth is measured with rack handles installed, but without the security bezel installed.
Weight (depending on the configuration)27.0 kg (59.6 lb) in maximum.
Processor (depending on model)Supports multi-core Intel Xeon processors, with integrated memory controller and Intel Ultra Path Interconnect (UPI) architecture.
  • Two processor sockets (expandable up to four) with minimal requirement of two installed on the system board.
  • Designed for LGA 3647 sockets
  • Scalable up to 28 cores
  • Supports Intel Extended Memory 32/64 Technology (EM32/64T)
Memory

See Memory module installation rules and order for detailed information about memory configuration and setup.

  • Minimum: 16 GB
  • Maximum:
    • RDIMM: 1.5 TB
    • LRDIMM: 3 TB
    • 3DS-RDIMM: 6 TB
    • DC Persistent Memory (DCPMM): 12 TB in Memory Mode

  • Memory module types:
    • Double-data-rate 4 (TruDDR4) error correcting code (ECC) 2666/2933 MT/s registered DIMM (RDIMM) or load reduced DIMM (LRDIMM)
    • DC Persistent Memory (DCPMM)
  • Capacity (depending on the model):
    • 8 GB, 16 GB, 32 GB, and 64 GB RDIMM
    • 64 GB LRDIMM
    • 64 GB and 128 GB 3DS-RDIMM
    • 128 GB, 256 GB, and 512 GB DCPMM
      Note
      DCPMM can be mixed with DRAM DIMMs with capacity of more than 16 GB. See DC Persistent Memory Module (DCPMM) setup for more information.
  • Slots: 24 two-way interleaved slots (expandable to 48)
Note
List of supported memory module is different for 1st generation (Skylake) and 2nd generation (Cascade Lake) Intel Xeon processors. Make sure to install compatible memory modules to avoid system error.For a list of supported DIMMs, see: Lenovo ServerProven website.
Drive expansionSixteen 2.5-inch drive bays:
  • Eight 2.5-inch hot-swap SATA/SAS drive bays (bay 0-3, 8-11)
  • Eight 2.5-inch hot-swap SATA/SAS/NVMe drive bays (bay 4-7, 12-15)
Expansion slotsEleven expansion slots:
  • Slot 1: PCI Express 3.0 x16 (supports PCIe switch card)
  • Slot 2: PCI Express 3.0 x8 (supports RAID adapters for SATA/SAS drives)
  • Slot 3 - 5: PCI Express 3.0 for PCIe riser-card with the following slots available depending on the riser-card installed:
    • x8/x8/x8 PCIe full-height riser assembly provides:
      • Slot 3: PCI Express 3.0 x8
      • Slot 4: PCI Express 3.0 x8
      • Slot 5: PCI Express 3.0 x8
    • x8/x8/x8ML2 PCIe full-height riser assembly provides:
      • Slot 3: PCI Express 3.0 x8
      • Slot 4: PCI Express 3.0 x8
      • Slot 5: Customized slot for x8 ML2 adapter
    • x8/x16ML2 PCIe full-height riser assembly provides:
      • Slot 3: PCI Express 3.0 x8
      • Slot 4: Not available
      • Slot 5: Customized slot for x16 ML2 adapter
  • Slot 6: Customized slot for dual M.2 backplane that supports M.2 drives in three different physical sizes:
    • 42 mm (2242)
    • 60 mm (2260)
    • 80 mm (2280)
  • Slot 7: Customized slot for LOM adapter
  • Slot 8: PCI Express 3.0 x8
  • Slot 9: PCI Express 3.0 x8
  • Slot 10: PCI Express 3.0 x8 (supports RAID adapters for SATA/SAS drives)
  • Slot 11: PCI Express 3.0 x16 (supports PCIe switch card)
Integrated functions
  • Lenovo XClarity Controller (XCC), which provides service processor control and monitoring functions, video controller, and remote keyboard, video, mouse, and remote drive capabilities.
  • One system-management RJ-45 connector on the rear to connect to a systems-management network. This connector is dedicated to the Lenovo XClarity Controller functions and runs at 1 GB speed.
  • Light-path diagnostics
  • Four universal serial bus (USB) ports:
    • Two on the front of the server
      • One USB 2.0 with Lenovo XClarity Controller management
      • One USB 2.0 or 3.0 (depending on the model)
    • Two USB 3.0 on the rear of the server
  • One serial port
NetworkThis server supports 1GbE and 10 GbE LOM adapters with the following requirements:
  • 1GbE LOM adapter: maximal bandwidth of network environment is 1GB.

  • 10GbE LOM adapter: minimal bandwidth of network environment is 1GB.

RAID adapter(depending on model)The following options with support for RAID levels 0, 1, and 10 are available for this server:
  • ThinkSystem RAID 530-8i PCIe 12 GB Adapter
  • ThinkSystem RAID 730-8i 1 GB Cache PCIe 12 GB Adapter
  • ThinkSystem RAID 730-8i 2 GB Cache PCIe 12 GB Adapter
  • ThinkSystem RAID 930-8i 2 GB Flash PCIe 12 GB Adapter
  • ThinkSystem RAID 930-16i 4 GB Flash PCIe 12 GB Adapter
  • ThinkSystem RAID 930-8e 4 GB Flash PCIe 12 GB Adapter
FansSix (60 mm x 38 mm) internal system fans (N+1 redundancy)
Electrical inputThis server comes with three types of power supply units:
  • 750-watt platinum power supply
    • Input power 115V or 220V ac
  • 1100-watt platinum power supply
    • Input power 115V or 220V ac
  • 1600-watt platinum power supply
    • Input power 220V ac
Two power supplies provide N+1 redundancy support.
CAUTION
  1. 240 V dc input (input range: 180-300 V dc) is ONLY supported in Chinese Mainland.

  2. Power supplies with 240 V dc are not hot-swappable. To remove the power cord, ensure you have turned off the server or disconnected the dc power sources at the breaker panel.

  3. In order for the ThinkSystem products to operate error free in both a DC or AC electrical environment, a TN-S earthing system which complies to 60364-1 IEC 2005 standard has to be present or installed.

Minimal configuration for debugging
  • Two processors in processor socket 1 and 2
  • Two DIMMs in slot 8 and 20
  • One power supply
  • One drive with RAID adapter and backplane (If OS is needed for debugging)
  • Six system fans (fan 1 to fan 6)
Acoustical noise emissions
  • Sound power, idling
    • 5.2 bels, minimum
    • 5.8 bels, typical
    • 6.4 bels, maximum
  • Sound power, operating
    • 5.8 bels, minimum
    • 6.8 bels, typical
    • 7.0 bels, maximum
Heat outputApproximate heat output:
  • Minimum configuration: 447 BTU, 131 W (in BTU per hour and watts)

  • Maximum configuration: 5265 BTU, 1543 W (in BTU per hour and watts)

EnvironmentThinkSystem SR850 complies with ASHRAE Class A2 specifications. Depending on the hardware configuration, some models comply with ASHRAE Class A3 and Class A4 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.
  • Air temperature:

    • Operating
      • ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
      • ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
    • Server off: 5°C to 45°C (41°F to 113°F)
    • Shipment/storage: -40°C to 60°C (-40°F to 140°F)
  • Maximum altitude: 3,050 m (10,000 ft)
  • Relative Humidity (non-condensing):
    • Operating
      • ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
      • ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
      • ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
    • Shipment/storage: 8% to 90%
  • Particulate contamination
    Attention
    Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
Operating systemsSupported and certified operating systems:
  • Microsoft Windows Server

  • VMware ESXi

  • Red Hat Enterprise Linux

  • SUSE Linux Enterprise Server

References:
Note
To maintain component reliability, system performance might vary at ambient temperature higher than 35°C while all the fans are functioning. With one fan failing, system performance might vary at ambient temperature higher than 27°C.