Rear view

This section contains information about the LEDs and connectors on the rear of the server.

Figure 1. Rear view

1/4 4U PCIe Riser Cage

Install PCIe adapters into these riser cages. See the following table for PCIe slots corresponding to the riser cages.

Table 2. 4U PCIe Riser Cages and corresponding PCIe slots
Riser cage typex8/x8/x8/x8 riser cagex16/x16 riser cage
1 Riser cage 1Slot 1NA
Slot 2Slot 2
Slot 3NA
Slot 4Slot 4
4 Riser cage 2Slot 9NA
Slot 10Slot 10
Slot 11NA
Slot 12Slot 12

2/3 7mm drive bays

Install 7mm drives to these bays. See Install a 7mm drive for more details.

5 AC power LED (green)

Each hot-swap power supply unit comes with one AC and one DC power LED. When the AC power LED is lit, it indicates that sufficient power is being supplied to the power supply through the power cord. During normal operation, both the AC and DC power LEDs are lit.

6 DC power LED (green)

Each hot-swap power supply unit comes with one AC and one DC power LED. When the DC power LED is lit, it indicates that the power supply is supplying adequate dc power to the system. During normal operation, both the AC and dc power LEDs are lit.

7 Power supply error LED (yellow)

When the power supply error LED is lit, it indicates that the power supply has failed.

8 Power supply units

Install power supply units to these bays, connect them to power cords. Make sure the power cords are connected properly. Following are the power supplies supported by this system:
  • 750-watt Platinum, input power 115 Vac / 230 Vac / 240 VDC
  • 750-watt Titanium, input power 230 Vac / 240 VDC
    Note
    When only two units of 750-watt Titanium power supply are installed, 240 VDC is not supported.
  • 1100-watt Platinum, input power 115 Vac / 230 Vac / 240 VDC
  • 1100-watt Titanium, input power 230 Vac / 240 VDC
  • 1800-watt Platinum, input power 230 Vac / 240 VDC
  • 1800-watt Titanium, input power 230 Vac / 240 VDC
  • 2600-watt Titanium, input power 230 Vac / 240 VDC

9/10/11 PCI Express 3.0

Install adapters, particularly RAID adapters, to these slots.

12 Serial connector

Connect a 9-pin serial device to this connector. The serial port is shared with XCC. XCC can take control of the shared serial port to redirect serial traffic, using Serial over LAN (SOL).

13 VGA connector

Connect a monitor to this connector.
Note
  • When the optional front VGA connector is in use, the rear one will be disabled.
  • The maximum video resolution is 1920 x 1200 at 60 Hz.

14 USB 3.1 connectors

Connect a USB device, such as a mouse, keyboard, or other devices, to either of these connectors.

15 XClarity Controller network connector

Use this connector to manage the server, by using a dedicated management network. If you use this connector, the Lenovo XClarity Controller cannot be accessed directly from the production network. A dedicated management network provides additional security by physically separating the management network traffic from the production network. You can use the Setup utility to configure the server to use a dedicated systems-management network or a shared network.

16 NMI button

Press this button to force a nonmaskable interrupt to the processor. You might have to use a pen or the end of a straightened paper clip to press the button. You can also use it to force a blue-screen memory dump. Use this button only when you are directed to do so by Lenovo Support.

17 OCP 3.0 Ethernet adapter

The OCP 3.0 Ethernet adapter provides two or four extra Ethernet connectors for network connections. One of the Ethernet connectors on the OCP 3.0 Ethernet adapter can also function as a management connector with shared management capacity. If the shared management connector fails, traffic can automatically switch over to another connector on the adapter.

The system may support a 2-port or a 4-port OCP module for network connections. Port numbering are shown in the illustrations below.
Figure 2. Port numbering — 2-port OCP module
Port numbering — 2-port OCP 3.0 Ethernet adapter
Figure 3. Port numbering — 4-port OCP 3.0 module
Port numbering — 4-port OCP 3.0 Ethernet adapter

18/19/20 PCIe riser

Install a PCIe riser card into these slots. See the following table for PCIe slots corresponding to the riser cards.
Table 3. PCIe riser cards and corresponding PCIe slots
Riser card typex16/x16 (x8 lanes) riser cardx16/x16/x16 riser card
20Slot 5 (x16, x8 lane)Slot 5 (x16)
19Slot 6 (x16, x8 lane)Slot 6 (x16)
18NASlot 7 (x16)

7 DC power LED (green)

Each hot-swap power supply unit comes with one AC and one DC power LED. When the DC power LED is lit, it indicates that the power supply is supplying adequate dc power to the system. During normal operation, both the AC and dc power LEDs are lit.

8 Power supply error LED (yellow)

When the power supply error LED is lit, it indicates that the power supply has failed.