Skip to main content

Specifications

The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.

Table 1. Specifications, Type 7Z59 and 7Z60.
SpecificationDescription
Dimension4U server
  • Height: 175 mm (6.9 inches)
  • Width:
    • With rack handles: 482 mm (19.0 inches)
    • Without rack handles: 434.4 mm (17.1 inches)
  • Depth: 835.9 mm (32.9 inches)
Note
The depth is measured with rack handles installed.
Weight (depending on the configuration)62 kg (136.7 lb) in maximum
Processor (depending on model)Supports multi-core Intel Xeon processors, with integrated memory controller and Intel Mesh UPI (Ultra Path Interconnect) topology.
  • Two processor sockets (expandable up to four) with minimal requirement of two installed on the system board.
  • Designed for LGA 4189 sockets
  • Scalable up to 28 cores
  • Supports 6 UPI links at 10.4 GT/s
Memory

See Memory module installation order for detailed information about memory configuration and setup.

  • Capacity
    • Minimum: 16 GB
    • Maximum:
      • RDIMM: 3 TB
      • 3DS-RDIMM: 6 TB
  • Memory module types:
    • Double-data-rate 4 (TruDDR4) error correcting code (ECC) 3200 MT/s registered DIMM (RDIMM) or 3DS RDIMM
    • Persistent Memory (PMEM)
  • Capacity (depending on the model):
    • RDIMM: 16 GB, 32 GB, and 64 GB
    • 3DS-RDIMM: 128 GB, 256 GB
    • PMEM: 128 GB, 256 GB, and 512 GB
      Note
      PMEMs can be mixed with DRAM DIMMs. See PMEM rules for more information.
  • Slots: 24 two-way interleaved slots (expandable to 48)

For a list of supported memory modules, see Lenovo ServerProven website.

Storage expansion
  • Forty-eight 2.5-inch drive bays:
    • Bay 0 to 23 support SAS/SATA/NVMe drives.
    • Bay 24 to 47 support SAS/SATA drives.
      Note
      When the following components are installed in the system, bay 24 to 47 are disabled, and the maximal supported drive quantity is 24.
      • PMEMs
      • DRAM DIMMs with 64 GB or larger capacity
      • Processors with 250 or more watts
  • Two 7mm/M.2 drive bays support SAS/SATA/NVMe drives.
Expansion slotsUp to seventeen slots:
  • Slot 1 to 4 (4U PCIe riser cage):
    • PCI Express 3.0 x8 (Slot 1, 2, 3, 4) or
    • PCI Express 3.0 x16 (Slot 2, 4)
  • Slot 5 to 7 (PCIe riser card):
    • PCI Express 3.0 x16 (Slot 5, 6, 7) or
    • PCI Express 3.0 x8 (Slot 5, 6)
  • Slot 8 (OCP 3.0 Ethernet adapter)
  • Slot 9 to 12 (4U PCIe riser cage):
    • PCI Express 3.0 x8 (Slot 9, 10, 11, 12) or
    • PCI Express 3.0 x16 (Slot 10, 12)
  • Slot 13: PCI Express 3.0 x16
  • Slot 14: PCI Express 3.0 x8
  • Slot 15: PCI Express 3.0 x8
  • Slot 16 to 17: 7mm/M.2 drive bays
Integrated functions
  • Lenovo XClarity Controller (XCC), which provides service processor control and monitoring functions, video controller, and remote keyboard, video, mouse, and remote drive capabilities.
  • One system-management RJ-45 connector on the rear to connect to a systems-management network. This connector is dedicated to the Lenovo XClarity Controller functions and runs at 1 GB speed.
  • Four universal serial bus (USB) ports:
    • Two on the front of the server:
      • One USB 2.0 with Lenovo XClarity Controller management
      • One USB 3.1
    • Two USB 3.1 on the rear of the server
  • One serial port
RAID adapter

(depending on model)

The following options with support for RAID levels 0, 1, and 10 are available for this server with up to four flash power modules:
  • ThinkSystem 430-8i SAS/SATA 12Gb HBA
  • ThinkSystem 430-16i SAS/SATA 12Gb HBA
  • ThinkSystem 430-8e SAS/SATA 12Gb HBA
  • ThinkSystem 430-16e SAS/SATA 12Gb HBA
  • ThinkSystem RAID 530-8i PCIe 12Gb Adapter
  • ThinkSystem RAID 530-16i PCIe 12Gb Adapter
  • ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 940-8i 4GB Flash PCIe Gen4 12Gb Adapter
  • ThinkSystem RAID 940-8i 8GB Flash PCIe Gen4 12Gb Adapter
  • ThinkSystem RAID 940-16i 4GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 940-16i 8GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 940-32i 8GB Flash PCIe 12Gb Adapter
  • x16 PCIe 1610-8P adapter
  • ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb Adapter
  • ThinkSystem RAID 5350-8i Flash PCIe 12Gb Adapter
  • ThinkSystem 4350-16i SAS/SATA 12Gb HBA
  • ThinkSystem 4350-8i SAS/SATA 12Gb HBA
Network

OCP Ethernet adapter with 1G/10G base-T and 10G/25G/50G SPF+

Fans
  • Eight (60 mm x 38 mm / 60 mm x 56 mm) internal single/dual rotor system fans (N+1 redundancy) :
    • Slot 1, 3, 4, 6: single-fan single/dual-rotor module
    • Slot 2, 5: dual-fan single/dual-rotor module
  • Four fans for 4U PCIe riser cages (Two fans for each unit)
Operating SystemSupported and certified operating systems:
  • Microsoft Windows Server
  • VMware ESXi
  • Red Hat Enterprise Linux
  • SUSE Linux Enterprise Server
References:
Electrical inputThis server supports up to four units of CFF V4 power supplies. Following is the list of supported types:
  • 750-watt Platinum, input power 115 Vac / 230 Vac / 240 VDC
  • 750-watt Titanium, input power 230 Vac / 240 VDC
    Note
    When only two units of 750-watt Titanium power supply are installed, 240 VDC is not supported.
  • 1100-watt Platinum, input power 115 Vac / 230 Vac / 240 VDC
  • 1100-watt Titanium, input power 230 Vac / 240 VDC
  • 1800-watt Platinum, input power 230 Vac / 240 VDC
  • 1800-watt Titanium, input power 230 Vac / 240 VDC
  • 2600-watt Titanium, input power 230 Vac / 240 VDC
CAUTION
  • 240 V dc input (input range: 180-300 V dc) is supported in Chinese Mainland ONLY.

  • Power supply with 240 V dc input cannot support hot-plugging power cord function. Before removing the power supply with dc input, please turn off server or disconnect dc power sources at the breaker panel or by turning off the power source. Then, remove the power cord.

Minimal configuration for debugging
  • Two processors in processor socket 1 and 2
  • Two DRAM DIMMs in slot 8 and 20
  • One power supply
  • One drive with RAID adapter and backplane (If OS is needed for debugging)
  • Eight system fans:

    • Upper row: fan 2 and fan 5
    • Lower row: fan 1 to 6
Acoustical noise emissionsThe server has the following acoustic noise emissions declaration:
  • Sound power level (LWAd)
    • Idling:
      • Typical: 6.1 Bel
      • Storage rich: 6.8 Bel
      • GPU: 7.4 Bel
    • Operating:
      • Typical: 7.0 Bel
      • Storage rich: 7.5 Bel
      • GPU: 8.2 Bel
  • Sound pressure level (LpAm):
    • Idling:
      • Typical: 47 dBA
      • Storage rich: 53 dBA
      • GPU: 60 dBA
    • Operating:
      • Typical: 55 dBA
      • Storage: 61 dBA
      • GPU: 67 dBA
Note
  • These sound levels were measured in controlled acoustical environments according to procedures specified by ISO7779 and are reported in accordance with ISO 9296.
  • The declared acoustic sound levels are based on the specified configurations, which may change slightly depending on configuration/conditions.
    • Typical configuration: four 165W processors, twenty-four 64 GB DIMMs, twenty-four SAS hard disk drives, 930-8i, Intel X710 10 GB 2 port, four 1100-watt power supply units
    • Storage rich configuration: four 205W processors, forty-eight 64 GB DIMMs, forty-eight SAS hard disk drives, 940-16i, Intel X710 10 GB 2 port, four 1100-watt power supply units
    • GPU configuration: four 205W processors, forty-eight 64 GB DIMMs, forty-eight SAS hard disk drives, 940-16i, Intel X710 10 GB 2 port, eight Nvidia Tesla T4, four 1800-watt power supply units
  • The declared acoustic noise levels may increase greatly, if high-power components are installed such as high-power NICs, high-power processors and GPUs.

  • Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room; the noise levels from other equipment; the room ambient temperature, and employee's location in relation to the equipment. Further, compliance with such government regulations depends on a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. Lenovo recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.
Ambient temperature managementAdjust ambient temperature when specific components are installed:
  • Keep ambient temperature to 35°C or lower when one or more of the following components are installed.
    • Processors with 165 to 205 watts
    • DRAM DIMMs with capacity larger than 64 GB
  • Keep ambient temperature to 35°C or lower when the following components are installed in the same unit.
    • Processors with 205 to 250 watts
    • 24 drives
  • Keep room temperature to 30°C or lower when one or more of the following components are installed.
    • Processors with 205 or more watts
    • Nvidia V100S
    • Nvidia T4
    • PMEMs
    Important
    To avoid throttling, follow the instructions below:
    • Make sure to adopt passive Direct Attach cables when ThinkSystem NVIDIA ConnectX-7 adapter is installed.
EnvironmentThinkSystem SR860 V2 complies with ASHRAE Class A2 specifications. Depending on the hardware configuration, some models comply with ASHRAE Class A3 and Class A4 specifications. System performance may be impacted when operating temperature is outside AHSARE A2 specification.
  • Air temperature:
    • Operating
      • ASHARE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
      • ASHARE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
      • ASHARE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
    • Server off: 5°C to 45°C (41°F to 113°F)
    • Shipment/storage: -40°C to 60°C (-40°F to 140°F)
  • Maximum altitude: 3,050 m (10,000 ft)
  • Relative Humidity (non-condensing):
    • Operating
      • ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
      • ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
      • ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
    • Shipment/storage: 8% to 90%
  • Particulate contamination
    Attention
    Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
Note
The server is designed for standard data center environment and recommended to be placed in industrial data center.