Skip to main content

FQXSFMA0005N : Memory is present within the system but could not be configured. Please verify that the memory configuration is valid. [arg1]

Memory is present within the system but could not be configured. Please verify that the memory configuration is valid. [arg1]

Severity

Error

User Action

Complete the following steps:

  1. Ensure one or more DIMMs are installed in the server.
  2. Resolve existing memory errors if they are present.
  3. If no memory fault is recorded in the logs and no DIMM connector error LEDs are lit, verify that all DIMM connectors are enabled using the Setup utility or the OneCLI utility.
  4. Reseat all DIMMs ensuring that DIMMs are installed in the correct population sequence, according to the service information for this product.
  5. Clear CMOS memory. Note that all firmware settings will revert to the defaults.
  6. Reflash UEFI firmware.
  7. If the problem persists, collect Service Data logs.
  8. Contact Lenovo Support.