Parts list

Identify each of the components that is available for your server with the parts list.

For more information about ordering parts:
  1. Go to Lenovo Data Center Support and navigate to the support page for your server.

  2. Click Parts.

  3. Enter the serial number to view a listing of parts for your server.

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

Note
Depending on the model, your server might look slightly different from the illustration.
Figure 1. Server components
Server components
The parts listed in the following table are identified as one of the following:
  • T1: Tier 1 customer replaceable unit (CRU). Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request with no service agreement, you will be charged for the installation.

  • T2: Tier 2 customer replaceable unit (CRU). You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.

  • F: Field replaceable unit (FRU). FRUs must be installed only by trained service technicians.

  • C: Consumable and Structural parts. Purchase and replacement of consumable and structural parts (components, such as a filler or bezel) is your responsibility. If Lenovo acquires or installs a structural component at your request, you will be charged for the service.

Table 1. Parts list
DescriptionTypeDescriptionType
For more information about ordering parts:
  1. Go to Lenovo Data Center Support and navigate to the support page for your server.

  2. Click Parts.

  3. Enter the serial number to view a listing of parts for your server.

1 Front top coverT130 2U performance heat sink and processor carrierF
2 Rear top coverT131 Lift handlesT1
3 Power supply unit fillerC32 Air baffle (rear, 3U standard PHM)T2
4 Power supply unitT133 M.2 driveT1
5 Power supply bracket (CRPS)T134 M.2 boot adapterT1
6 Power distribution boardT235 M.2 drive retainerT1
7 PCIe riser cageT236 Air baffle (rear, 2U performance PHM)T2
8 PCIe riser cable retainerT137 2.5-inch drive backplaneT1
9 PCIe riser cardT238 2.5-inch drive filler (1-bay)C
10 PCIe adapterT139 2.5-inch hot-swap driveT1
11 7mm drive cageT140 Flash power moduleT1
12 7mm drive backplaneT141 Air baffle (front)T1
13 PCIe riser extenderT242 Fan cageT1
14 PCIe riser cage fillerC43 2.5-inch drive filler (8-bay)C
15 7mm drive fillerC44 Fan moduleT1
16 7mm driveT145 External diagnostics handsetT1
17 OCP moduleT146 Mechanical parts kit (power supply key, serial port filler, and screws)T1
18 OCP slot fillerC47 Power supply key (CFFv4)T1
19 CrossbarT148 Intrusion switchT1
20 ChassisF49 Drive backplane carrierT2
21 Slide rail kitT250 Cable management armT2
22 System I/O boardF51 Suction cupC
23 Firmware and RoT security moduleF52 GPU adapter link bridgeT1
24 ProcessorF53 Full-length GPU adapterT1
25 MicroSD cardF54 Labels kit (PCIe riser cables)T1
26 Memory moduleT1/F155 Cable2T1
27 Processor boardF56 System service labelT1
28 CMOS battery (CR2032)C57 Management NIC adapterT1
29 3U standard heat sink and processor carrierF  
Note
  • 1 For memory modules in memory module slot 1-32 when 2U performance PHM are installed.

  • 2 For PCIe riser cable replacement, make sure to order the 54 Labels kit (PCIe riser cables).