Environmental specifications
Summary of the environmental specifications of server. Depending on the model, some features might not be available, or some specifications might not apply.
Acoustical noise emissions
The server has the following acoustic noise emissions declaration:
Acoustic performance @ 25°C ambient | Working mode | Configuration | |
---|---|---|---|
Typical | Max. | ||
Declared mean A-weighted sound power level, LWA,m (B) Statistical adder for verification, Kv (B) = 0.4 | Idle | 6.8 | 6.8 |
Operating mode 1 | 7.2 | 7.9 | |
Operating mode 2 | 7.9 | 8.5 | |
Declared mean A-weighted emission sound pressure level, LpA,m (dB) Bystander position | Idle | 53 | 53 |
Operating mode 1 | 58 | 66 | |
Operating mode 2 | 66 | 72 |
These sound levels were measured in controlled acoustical environments according to procedures specified by ISO7779 and are reported in accordance with ISO 9296.
Idle mode is the steady state in which the server is powered on but not operating any intended function. Operating mode 1 is 50% CPU TDP. Operating mode 2 is 100% CPU TDP.
- The declared acoustic sound levels are based on the following configurations, which may change depending on configuration or conditions.
Typical: 4 x 270W CPUs, 32 x 64 GB RDIMMs, 24 x 2.5" SAS HDDs, 1 x RAID 545-8i, 1 x Intel E610-T4 10GBASE-T 4-port OCP, 4 x 2000W PSUs
Max.: 4 x 350W CPUs, 64 x 64 GB RDIMMs, 48 x 2.5" SAS HDDs, 3 x RAID 940-16i, 2 x Intel E610-T4 10GBASE-T 4-port OCP, 4 x 3200W PSUs
Government regulations (such as those prescribed by OSHA or European Community Directives) may govern noise level exposure in the workplace and may apply to you and your server installation. The actual sound pressure levels in your installation depend upon a variety of factors, including the number of racks in the installation; the size, materials, and configuration of the room; the noise levels from other equipment; the room ambient temperature, and employee's location in relation to the equipment. Further, compliance with such government regulations depends on a variety of additional factors, including the duration of employees' exposure and whether employees wear hearing protection. Lenovo recommends that you consult with qualified experts in this field to determine whether you are in compliance with the applicable regulations.
Ambient temperature management
Manage the ambient temperature for your server depending on the specific hardware components installed.
Server models with 2.5-inch drive bays
System fan | Max. ambient temp.1 | CPU TDP | DIMM capacity (per module) | Max. drive qty. | Rear M.2 drives | GPU adapter | NIC adapter |
---|---|---|---|---|---|---|---|
Standard fans | 40°C/45°C | <= 165W | <= 32 GB | 48 | None | None | None |
Standard fans | 35°C | <=210W | <= 32 GB | 48 | None | None | None |
Standard fans | 30°C | <=270W | <= 64 GB2 | 48 | 2 | None | None |
Standard fans | 25°C | <=270W | <= 64 GB2 | 48 | 2 | None | See note3 |
Performance fans | 40°C/45°C | <=270W | <= 32 GB | 48 | None | None | None |
Performance fans | 35°C | <=350W | <= 64 GB | 48 | None | None | See note3,4 |
Performance fans | 30°C | <=350W | <= 128 GB | 48 | 2 | See note5 | See note3,4,5 |
Performance fans | 25°C | <=350W | <= 128 GB | 48 | 2 | See note5 | See note3,4,5 |
Ultra fans | 40°C/45°C | <=270W | <= 64 GB | 48 | None | None | None |
Ultra fans | 35°C | <=350W | <= 128 GB | 48 | 2 | None | See note3,4 |
Ultra fans | 30°C | <=350W | <= 128 GB | 48 | 2 | See note6 | See note3,4,5 |
Ultra fans | 25°C | <=350W | <= 256 GB7 | 48 | 2 | See note6 | See note3,4,5 |
The server's performance may be impacted if operated under 40°C/45°C.
The 64 GB RDIMMs are supported in servers with only 24 x 2.5-inch drives.
NIC adapters without active optic cables (AOC) are supported.
NIC adapters with AOC cables are supported. When the CPU TDP is 270W or lower, the ambient temperature can be up to 35°C.
The Broadcom BCM57608 2x200G OCP Ethernet adapter is supported in servers with only 24 x 2.5-inch drives.
A maximum of four double-wide (DW) GPU adapters or eight single-wide (SW) GPU adapters are supported. When DW GPU adapters are installed, the 2U performance heat sinks must be used for processor 1 and processor 2.
The 256 GB RDIMMs are supported in servers with only 24 x 2.5-inch drives.
Server models with E3.S bays
System fan | Max. ambient temp. | CPU TDP | DIMM capacity (per module) | Max. drive qty.1 | Rear M.2 drives | GPU adapter | NIC adapter |
---|---|---|---|---|---|---|---|
Ultra fans | 35°C | <=350W | <= 128 GB | 32 + 24 | None | None | See note2,3 |
Ultra fans | 30°C | <=350W | <= 128 GB | 32 + 24 | 2 | See note4 | See note2,3 |
Ultra fans | 25°C | <=350W | <= 128 GB | 32 + 24 | 2 | See note4 | See note2,3 |
Supports up to 32 x E3.S 1T drives and 24 x 2.5-inch drives.
NIC adapters without active optic cables (AOC) are supported.
NIC adapters with AOC cables are supported. When the CPU TDP is 270W or lower, the ambient temperature can be up to 35°C.
A maximum of four double-wide (DW) GPU adapters or eight single-wide (SW) GPU adapters are supported. When DW GPU adapters are installed, the 2U performance heat sinks must be used for processor 1 and processor 2.
Environment
Environment |
---|
ThinkSystem SR860 V4 complies with ASHRAE Class A2 specifications under most hardware configurations, and depending on specific hardware configuration, it may also comply with ASHRAE Class A3, Class A4, or Class H1 specifications. Refer to Ambient temperature management for information about temperature requirement for specific hardware. The server's performance may be impacted if operated outside the specified ASHRAE temperature classes it complies with. Note The server is designed for standard data center environment and recommended to be placed in industrial data center.
|
Water requirements
Water requirements | ||||||||
---|---|---|---|---|---|---|---|---|
ThinkSystem SR860 V4 is supported in the following environment:
Attention The water required to initially fill the system side cooling loop must be reasonably clean, bacteria-free water (<100 CFU/ml) such as de-mineralized water, reverse osmosis water, de-ionized water, or distilled water. The water must be filtered with an in-line 50 micron filter (approximately 288 mesh). The water must be treated with anti-biological and anti-corrosion measures. Environment quality must be maintained over the lifetime of the system to receive warranty and support on affecting components. For more information, see |