FQXSPUN0055M : The RAID controller in PCI slot [arg1] is in critical state. Battery is in non-optimal state.
The RAID controller in PCI slot [arg1] is in critical state. Battery is in non-optimal state.
This message is for the use case when an implementation has detected a Sensor transitioned to critical from less severe.
Severity
Error
Alert Category
Critical - Other
Serviceable
Yes
SNMP Trap ID
50
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check whether a RAID battery is installed and attached.
- If no RAID battery is installed, please ignore this message.
- If a RAID battery is installed, check the RAID battery for air flow obstruction and ensure that battery cables are properly connected.
- If the problem persists, collect service data log from the XCC WebGUI and contact Lenovo Support.
Entregar comentarios