Power-supply LEDs
This section describes the power-supply LEDs on the rear of the server and the suggested actions to correct the detected problems.
- One microprocessor
- One 4 GB DIMM
- Power supply
- Power cord
- Four cooling fans
For the locations of the LEDs and connectors on the rear of the server, see Rear view.
The following table describes the problems that are indicated by various combinations of the power-supply LEDs and suggested actions to correct the detected problems.
ac power LED | dc power LED | Power-supply error LED | Description | Action |
---|---|---|---|---|
On | On | Off | Normal operation | No action needed. |
Off | Off | Off | No ac power to the server or a problem with the ac power source. This symptom is a normal condition when no ac power is present. |
|
On | Off | Off | Faulty system board or faulty power supply The symptom typically indicates that a power supply is not fully seated. This is a normal condition before turning on the system. |
|
On | Off or Flashing | On | Faulty power supply | Replace the power supply. |
On | On | On | Power supply is faulty but still operational. | Replace the power supply. |