| The amount of system memory that is displayed is less than the amount of installed physical memory. | Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server. Make sure that:No error LEDs are lit on the operator information panel.No DIMM error LEDs are lit on the system board.Memory mirroring does not account for the discrepancy.The memory modules are seated correctly.You have installed the correct type of memory.If you changed the memory, you updated the memory configuration in the Setup utility.All banks of memory are enabled. The server might have automatically disabled a memory bank when it detected a problem, or a memory bank might have been manually disabled.There is no memory mismatch when the server is at the minimum memory configuration.
Reseat the DIMMs, and then restart the server.Check the POST error log:If a DIMM was disabled by a systems-management interrupt (SMI), replace the DIMM.If a DIMM was disabled by the user or by POST, reseat the DIMM; then, run the Setup utility and enable the DIMM.
Check that all DIMMs are initialized in the Setup utility; then, run memory diagnostics (see Running the diagnostic programs).Reverse the DIMMs between the channels (of the same microprocessor), and then restart the server. If the problem is related to a DIMM, replace the failing DIMM.Re-enable all DIMMs using the Setup utility, and then restart the server.(Trained service technician only) Install the failing DIMM into a DIMM connector for microprocessor 2 (if installed) to verify that the problem is not the microprocessor or the DIMM connector.(Trained service technician only) Replace the system board.
 | 
| Multiple rows of DIMMs in a branch are identified as failing. The highest-numbered DIMM failed disabling other DIMM(s) in the same channel. | Each time you install or remove a DIMM, you must disconnect the server from the power source; then, wait 10 seconds before restarting the server. Reseat the DIMMs; then, restart the server.Remove the DIMM with lit error LED and replace it with an identical known good DIMM; then, restart the server. Repeat as necessary. If the failures continue after all identified DIMMs are replaced, go to step 4.Return the removed DIMMs, one at a time, to their original connectors, restarting the server after each DIMM, until a DIMM fails. Replace each failing DIMM with an identical known good DIMM, restarting the server after each DIMM replacement. Repeat step 3 until you have tested all removed DIMMs.Replace the DIMM with lit error LED; then, restart the server. Repeat as necessary.Reverse the DIMMs between the channels (of the same microprocessor), and then restart the server. If the problem is related to a DIMM, replace the failing DIMM.(Trained service technician only) Install the failing DIMM into a DIMM connector for microprocessor 2 (if installed) to verify that the problem is not the microprocessor or the DIMM connector.(Trained service technician only) Replace the system board.
 |