80010b01-1302ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted. (PSU 2 Amb Temp)
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted. (PSU 2 Amb Temp)
This message is for the use case when an implementation has detected an Upper Non-recoverable sensor going high has asserted.
May also be shown as 80010b011302ffff or 0x80010b011302ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
- Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server), that the air baffle is in place and correctly installed, and that the server cover is installed and completely closed.
- Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
- Make sure that the heat sink for microprocessor n.
- (Trained technician only) Replace system board.
フィードバックを送る