Skip to main content

Test results for the DSA system management test

The following messages can result when you run the DSA system management test.

  • 166-000-001 : IMM I2C Test Passed

    IMM I2C Test Passed.
    Recoverable
    No
    Severity
    Event
    Serviceable
    No
    Automatically notify support
    No
    Related links
  • 166-801-001 : IMM I2C Test Aborted

    IMM returned incorrect response length.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-802-001 : IMM I2C Test Aborted

    Test cannot be completed for unknown reason.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-803-001 : IMM I2C Test Aborted

    Node Busy. Try later.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-804-001 : IMM I2C Test Aborted

    Invalid Command.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-805-001 : IMM I2C Test Aborted

    Invalid Command for given LUN.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-806-001 : IMM I2C Test Aborted

    Timeout while processing command.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-807-001 : IMM I2C Test Aborted

    Out of space.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-808-001 : IMM I2C Test Aborted

    Reservation Canceled or Invalid Reservation ID.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-809-001 : IMM I2C Test Aborted

    Request data truncated.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-810-001 : IMM I2C Test Aborted

    Request data length invalid.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-811-001 : IMM I2C Test Aborted

    Request data field length limit exceeded.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-812-001 : IMM I2C Test Aborted

    Parameter out of range.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-813-001 : IMM I2C Test Aborted

    Cannot return number of requested data bytes.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-814-001 : IMM I2C Test Aborted

    Requested Sensor, data, or record not present.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-815-001 : IMM I2C Test Aborted

    Invalid data field in Request.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-816-001 : IMM I2C Test Aborted

    Command illegal for specified sensor or record type.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-817-001 : IMM I2C Test Aborted

    Command response could not be provided.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-818-001 : IMM I2C Test Aborted

    Cannot execute duplicated request.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-819-001 : IMM I2C Test Aborted

    Command response could not be provided. SDR Repository in?update mode.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-820-001 : IMM I2C Test Aborted

    Command response could not be provided. Device in firmware update mode.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-821-001 : IMM I2C Test Aborted

    Command response could not be provided. BMC initialization in progress.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-822-001 : IMM I2C Test Aborted

    Destination unavailable.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-823-001 : IMM I2C Test Aborted

    Cannot execute command. Insufficient privilege level.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-824-001 : IMM I2C Test Aborted

    Cannot execute command.
    Recoverable
    No
    Severity
    Warning
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    Related links
  • 166-901-001 : IMM I2C Test Failed

    IMM Indicates failure in RTMM bus (BUS 0).
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    3. Run the test again.
    4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 166-904-001 : IMM I2C Test Failed

    IMM Indicates failure in PCA9543--4-Channel I2C Switch (BUS 3).
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    3. Run the test again.
    4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 166-905-001 : IMM I2C Test Failed

    IMM Indicates failure in Power paddle card (BUS 4).
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    3. Run the test again.
    4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links
  • 166-908-001 : IMM I2C Test Failed

    IMM Indicates failure in the PCA9557 bus (BUS 7).
    Recoverable
    No
    Severity
    Error
    Serviceable
    Yes
    Automatically notify support
    No
    User Response
    Perform the actions mentioned one at a time and try the test after each action:
    1. Turn off the system and disconnect it from power. Wait for 45 seconds. Reconnect it to power.
    2. Make sure that DSA and BMC/IMM are at the latest level.
    3. Run the test again.
    4. If failure remains, refer to "Troubleshooting by symptom" in the system "Installation and Service Guide" for the next corrective action.
    Related links