8007010d-2582ffff : Sensor [SensorElementName] has transitioned from normal to non-critical state. (RAID Vol State)
Sensor [SensorElementName] has transitioned from normal to non-critical state. (RAID Vol State)
This message is for the use case when an implementation has detected a Sensor transitioned to non-critical from normal.
May also be shown as 8007010d2582ffff or 0x8007010d2582ffff
Severity
Warning
Alert Category
Warning - Other
Serviceable
Yes
SNMP Trap ID
60
Automatically Notify Support
No
User Response
- Run the hard disk drive diagnostic test on drive n.
- Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
- Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)
Give feedback