806f0107-0301ffff : An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 1)
An Over-Temperature Condition has been detected on [ProcessorElementName]. (CPU 1)
This message is for the use case when an implementation has detected an Over-Temperature Condition Detected for Processor.
May also be shown as 806f01070301ffff or 0x806f01070301ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
- Make sure that the fans are operating. There are no obstructions to the airflow (front and rear of the server), the air baffles are in place and correctly installed, and the server cover is installed and completely closed.
- Make sure that the heat sink for microprocessor n is installed correctly.
- (Trained technician only) Replace microprocessor n. (n = microprocessor number)
Give feedback