806f0a0c-2007ffff : An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on Subsystem [MemoryElementName]. (DIMM 7)
This message is for the use case when an implementation has detected an Over Temperature Condition for Memory that has been Detected.
May also be shown as 806f0a0c2007ffff or 0x806f0a0c2007ffff
Severity
Error
Alert Category
Critical - Temperature
Serviceable
Yes
SNMP Trap ID
0
Automatically Notify Support
No
User Response
- Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in place and correctly installed, and that the server cover is installed and completely closed.
- Make sure that ambient temperature is within the specifications.
- If a fan has failed, complete the action for a fan failure.
- Replace DIMM n. (n = DIMM number)