volts command
Use this command to display the server voltage information.
Use the volts command to display all the voltages and voltage thresholds. The same set of voltages are displayed as in the web interface.
Syntax:
volts
Example:
system> volts
HSL SSL WL WRL V WRH WH SSH HSH
---------------------------------------------------------------
CMOS Battery N/A 2.25 2.39 0.03 3.12 0.03 N/A N/A N/A
system>
Note
The output has the following column headings:
- HSL: hard shutdown low (Lower non-recoverable Threshold)
- SSL: soft shutdown low (Lower critical Threshold)
- WL: warning low (Lower non-critical Threshold)
- WRL: warning reset low (Negative-going Threshold Hysteresis value)
- V: voltage (current value)
- WRH: warning reset high (Positive-going Threshold Hysteresis value)
- WH: warning high (Upper non-critical Threshold)
- SSH: soft shutdown high (Upper critical Threshold)
- HSH: hard shutdown high (Upper non-recoverable Threshold)
Give documentation feedback