IMM self tests
Use this information to resolve IMM self-test errors by referencing the error codes and following the suggested corrective actions.
For information about the IBM WebSphere DataPower Integration Blade XI50B appliance, see the Installation and User's Guide that came with the blade appliance.
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
| ||
---|---|---|
Error code | Description | Action |
166-901-xxx | Failed the IMM test due to a failure in the host bus. |
|
166-902-xxx | Failed the IMM self test due to a failure in SIO Bus and DASD SEP. |
|
166-903-xxx | Failed the IMM self test due to a failure in the LAN bus. |
|
166-904-xxx | Failed the IMM self test due to a failure in the main expander. |
|
166-905-xxx | Failed the IMM self test due to a failure in the CPU/VRD bus. | Note Ignore this error if the direct access storage device (DASD) planar is not installed.
|
166-906-xxx | Failed the IMM self test due to a failure in VPD or Power PSOC. |
|
166-907-xxx | Failed the IMM self test due to a failure in the EXP A0 bus. |
|
166-908-xxx | Failed the IMM self test due to a failure in the EXP A1 bus. |
|
166-909-xxx | Failed the IMM self test due to a failure in the EXP B bus. |
|
166-910-xxx | Failed the IMM self test due to a failure in the onboard legacy daughter card. |
|
166-911-xxx | Failed the IMM self test due to a failure in the BSE-3 PCI-X A slot. |
|
166-912-xxx | Failed the IMM self test due to a failure in the BSE-3 PCI-X B slot. |
|
Give documentation feedback