Cabling disk shelves with IOM12 modules for a hot-add
You cable the SAS connections, shelf-to-shelf and controller-to-stack, as applicable for hot-added disk shelves so they have connectivity to the system.
Before you begin
You must have met the requirements in the Requirements for a hot-adding disk shelves with IOM12 modules
section and installed, powered on, and set shelf IDs for each disk shelf as instructed in the Installing disk shelves with IOM12 modules for a hot-add
section.
About this task
- For an explanation and examples of shelf-to-shelf
standard
cabling and shelf-to-shelfdouble-wide
cabling, see theShelf-to-shelf SAS connection rules
section. - Instructions about how to read a worksheet to cable controller-to-stack connections can be found towards the back of this guide.
- After you have cabled the hot-added disk shelves, ONTAP recognizes them: disk ownership is assigned if disk ownership automatic assignment is enabled; disk shelf (IOM) firmware and disk drive firmware should automatically update if needed; and if in-band ACP is enabled on your configuration, it is automatically enabled on the hot-added disk shelves.NoteFirmware updates can take up to 30 minutes.
Give feedback