Miscellaneous

You may configure the following options for your preferences:
  • Maximum Healthy Temperature: The color (blue or orange) in dashboard would be affected by this option. Recommended value is 27 °C. This setting option does not impact all the temperature based threshold.

  • Enable/ disable playing sound for custom and critical events.

  • Enable/ disable blinking the browser title for custom and critical events.

  • Specify ‘Power Usage Effectiveness’ of your datacenter. PUE=Total Facility Energy / IT Equipment Energy. It is used to estimate Metrics in Temperature / Power page.

  • Specify ‘Electricity Cost per kWh’ and ‘Currency’. If the two values are set, the energy cost of the specified entity will be calculated and displayed with the energy consumption in its ‘Temperature/Power’ tab.

  • Enable/ disable Predictive Power Capping. Predictive Power Capping is a policy where excursions over the limit are not allowed. The important aspect of this feature is that you are willing to sacrifice performance by overly constraining power to avoid violating the power cap. If it is enabled, power policies on all the servers with Intel® Intelligent Power Node Manager 3.0 will be impacted.

Note
The blink of the browser title may behave differently in different web browsers and operating system settings.