Verifying port configuration (MetroCluster FC configurations only)

You must set the environmental variables on the node and then power it off to prepare it for MetroCluster configuration.

About this task

This procedure is performed with the replacement controller modules in Maintenance mode.

The steps to check configuration of ports is needed only on systems in which FC or CNA ports are used in initiator mode.

  1. In Maintenance mode, enter the following command to restore the FC port configuration: ucadmin modify -m fc -t initator adapter_name

    If you only want to use one of a port pair in the initiator configuration, enter a precise adapter_name.

  2. Take one of the following actions, depending on your configuration:
    If the FC port configuration is...Then...
    The same for both portsAnswer y when prompted by the system since modifying one port in a port pair modifies the other port as well.
    Different
    1. Answer n when prompted by the system.

    2. Enter the following command to restore the FC port configuration: ucadmin modify -m fc -t initator|target adapter_name

  3. Exit Maintenance mode by entering the following command: halt
    After you issue the command, wait until the system stops at the LOADER prompt.
  4. Boot the node back into Maintenance mode for the configuration changes to take effect: boot_ontap maint
  5. Verify the values of the variables by entering the following command: ucadmin show
  6. Exit Maintenance mode and display the LOADER prompt:halt