Skip to main content

Hot-swapping FibreBridge 6500N bridges to create a pair of FibreBridge 7600N bridge

To hot-swap one or two FibreBridge 6500N bridges to create a configuration with a pair of FibreBridge 7600N bridge, you must replace the bridges one at a time and follow the correct cabling procedure. The new cabling is different from the original cabling.

About this task

You can also use this procedure if the following conditions are true:

  • You are replacing a pair of FibreBridge 6500N bridges that are both connected to the same stack of SAS storage.

  • You previously replaced one FibreBridge 6500N bridge in the pair, and your storage stack is configured with one FibreBridge 6500N bridge and one FibreBridge 7600N bridge.

    In this case, you should begin with Step 3.

The following diagram shows an example of the initial configuration, in which four FibreBridge 6500N bridges are connecting two SAS storage stacks:



  1. Using the following guidelines, hot-swap the top FibreBridge 6500N bridge with a FibreBridge 7600N bridge using the procedure in Hot-swapping a FibreBridge 6500N bridge with a FibreBridge 7600N bridge:

    • Connect the FibreBridge 7600N bridge FC1 port to the switch or controller.

      This is the same connection that was made to the FibreBridge 6500N bridge FC1 port.

    • Do not connect the FibreBridge 7600N bridge FC2 port at this time.

    The following diagram shows that bridge_A_1a has been replaced and is now a FibreBridge 7600N bridge:



  2. Confirm connectivity to the bridge-connected disks and that the new FibreBridge 7600N is visible in the configuration: run local sysconfig -v

    Example

    node_A_1> run local sysconfig -v
    Lenovo Release 9.6P5: Fri Dec 13 13:23:47 EST 2019
    System ID: 0536872165 (node_A_1); partner ID: 0536872141 (node_B_1)
    System Serial Number: 940001025465 (node_A_1)
    System Rev: A4
    System Storage Configuration: Multi-Path HA<=== Configuration should be multi-path HA
    .
    .
    .
    slot 0: FC Host Adapter 0g (QLogic 8324 rev. 2, N-port, <UP>)<=== Initiator port
    Firmware rev: 7.5.0
    Flash rev: 0.0.0
    Host Port Id: 0x60100
    FC Node Name: 5:00a:098201:bae312
    FC Port Name: 5:00a:098201:bae312
    SFP Vendor: FINISAR CORP.
    SFP Part Number: FTLF8529P3BCVAN1
    SFP Serial Number: URQ0R1R
    SFP Capabilities: 4, 8 or 16 Gbit
    Link Data Rate: 16 Gbit
    Switch Port: brcd6505-fcs40:1
    <List of disks visible to port>
    ID Vendor Model FW Size
    brcd6505-fcs40:12.126L1527 : LENOVO X302_HJUPI01TSSM NA04 847.5GB (1953525168 512B/sect)
    brcd6505-fcs40:12.126L1528 : LENOVO X302_HJUPI01TSSA NA02 847.5GB (1953525168 512B/sect)
    .
    .
    .
    <List of FC-to-SAS bridges visible to port>
    FC-to-SAS Bridge:
    brcd6505-fcs40:12.126L0 : ATTO FibreBridge7600N A30H FB7600N100104<===
    brcd6505-fcs42:13.126L0 : ATTO FibreBridge6500N 1.61 FB6500N102980
    brcd6505-fcs42:6.126L0 : ATTO FibreBridge6500N 1.61 FB6500N101167
    brcd6505-fcs42:7.126L0 : ATTO FibreBridge6500N 1.61 FB6500N102974
    .
    .
    .
    <List of storage shelves visible to port>
    brcd6505-fcs40:12.shelf6: DS4243 Firmware rev. IOM3 A: 0200 IOM3 B: 0200
    brcd6505-fcs40:12.shelf8: DS4243 Firmware rev. IOM3 A: 0200 IOM3 B: 0200
    .
    .
    .

  3. Using the following guidelines, hot-swap the bottom FibreBridge 6500N bridge with a FibreBridge 7600N bridge using the procedure in Hot-swapping a FibreBridge 6500N bridge with a FibreBridge 7600N bridge:

    • Connect the FibreBridge 7600N bridge FC2 port to the switch or controller.

      This is the same connection that was made to the FibreBridge 6500N bridge FC1 port.

    • Do not connect the FibreBridge 7600N bridge FC1 port at this time.

  4. Confirm connectivity to the bridge-connected disks: run local sysconfig -v

    The output shows the disks attached to the initiator ports on the controller, and identifies the shelves connected to the FC-to-SAS bridges:

    Example

    node_A_1> run local sysconfig -v
    Lenovo Release 9.6P5: Fri Dec 13 13:23:47 EST 2019
    System ID: 0536872165 (node_A_1); partner ID: 0536872141 (node_B_1)
    System Serial Number: 940001025465 (node_A_1)
    System Rev: A4
    System Storage Configuration: Multi-Path HA<=== Configuration should be multi-path HA
    .
    .
    .
    slot 0: FC Host Adapter 0g (QLogic 8324 rev. 2, N-port, <UP>)<=== Initiator port
    Firmware rev: 7.5.0
    Flash rev: 0.0.0
    Host Port Id: 0x60100
    FC Node Name: 5:00a:098201:bae312
    FC Port Name: 5:00a:098201:bae312
    SFP Vendor: FINISAR CORP.
    SFP Part Number: FTLF8529P3BCVAN1
    SFP Serial Number: URQ0R1R
    SFP Capabilities: 4, 8 or 16 Gbit
    Link Data Rate: 16 Gbit
    Switch Port: brcd6505-fcs40:1
    <List of disks visible to port>
    ID Vendor Model FW Size
    brcd6505-fcs40:12.126L1527 : LENOVO X302_HJUPI01TSSM NA04 847.5GB (1953525168 512B/sect)
    brcd6505-fcs40:12.126L1528 : LENOVO X302_HJUPI01TSSA NA02 847.5GB (1953525168 512B/sect)
    .
    .
    .
    <List of FC-to-SAS bridges visible to port>
    FC-to-SAS Bridge:
    brcd6505-fcs40:12.126L0 : ATTO FibreBridge7600N A30H FB7600N100104
    brcd6505-fcs42:13.126L0 : ATTO FibreBridge7600N A30H FB7600N100104
    .
    .
    .
    <List of storage shelves visible to port>
    brcd6505-fcs40:12.shelf6: DS4243 Firmware rev. IOM3 A: 0200 IOM3 B: 0200
    brcd6505-fcs40:12.shelf8: DS4243 Firmware rev. IOM3 A: 0200 IOM3 B: 0200
    .
    .
    .