Zoning for FC-VI ports
For each DR group in the MetroCluster, you must configure two zones for the FC-VI connections that allow controller-to-controller traffic. These zones contain the FC switch ports connecting to the controller module FC-VI ports. These zones are Quality of Service (QoS) zones.
A QoS zone name starts with the prefix QOSHid_, followed by a user-defined string to differentiate it from a regular zone. These QoS zones are the same regardless of the model of FibreBridge bridge that is being used.
Each zone contains all the FC-VI ports, one for each FC-VI cable from each controller. These zones are configured for high priority.
The following tables show the FC-VI zones for two DR groups.
DR group 1 : QOSH1 FC-VI zone for FC-VI port a / c | |||||
---|---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... | |
B6505 / B6510 | DB620S | ||||
FC_switch_A_1 | A | 5 | 0 | 0 | controller_A_1 port FC-VI a |
1 | 1 | controller_A_1 port FC-VI c | |||
4 | 4 | controller_A_2 port FC-VI a | |||
5 | 5 | controller_A_2 port FC-VI c | |||
FC_switch_B_1 | B | 7 | 0 | 0 | controller_B_1 port FC-VI a |
1 | 1 | controller_B_1 port FC-VI c | |||
4 | 4 | controller_B_2 port FC-VI a | |||
5 | 5 | controller_B_2 port FC-VI c |
Zone in Fabric_1 | Member ports |
---|---|
QOSH1_MC1_FAB_1_FCVI | 5,0;5,1;5,4;5,5;7,0;7,1;7,4;7,5 |
DR group 1 : QOSH1 FC-VI zone for FC-VI port b / d | |||||
---|---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... | |
B6505 / B6510 | DB620S | ||||
FC_switch_A_2 | A | 6 | 0 | 0 | controller_A_1 port FC-VI b |
1 | 1 | controller_A_1 port FC-VI d | |||
4 | 4 | controller_A_2 port FC-VI b | |||
5 | 5 | controller_A_2 port FC-VI d | |||
FC_switch_B_2 | B | 8 | 0 | 0 | controller_B_1 port FC-VI b |
1 | 1 | controller_B_1 port FC-VI d | |||
4 | 4 | controller_B_2 port FC-VI b | |||
5 | 5 | controller_B_2 port FC-VI d |
Zone in Fabric_1 | Member ports |
---|---|
QOSH1_MC1_FAB_2_FCVI | 6,0;6,1;6,4;6,5;8,0;8,1;8,4;8,5 |
DR group 2 : QOSH2 FC-VI zone for FC-VI port a / c | |||||
---|---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... | |
B6510 | DB620S | ||||
FC_switch_A_1 | A | 5 | 24 | 18 | controller_A_3 port FC-VI a |
25 | 19 | controller_A_3 port FC-VI c | |||
28 | 22 | controller_A_4 port FC-VI a | |||
29 | 23 | controller_A_4 port FC-VI c | |||
FC_switch_B_1 | B | 7 | 24 | 18 | controller_B_3 port FC-VI a |
25 | 19 | controller_B_3 port FC-VI c | |||
28 | 22 | controller_B_4 port FC-VI a | |||
29 | 23 | controller_B_4 port FC-VI c |
Zone in Fabric_1 | Member ports |
---|---|
QOSH2_MC2_FAB_1_FCVI (B6510) | 5,24;5,25;5,28;5,29;7,24;7,25;7,28;7,29 |
DR group 2 : QOSH2 FC-VI zone for FC-VI port b / d | |||||
---|---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... | |
B6510 | DB620S | ||||
FC_switch_A_2 | A | 6 | 24 | 18 | controller_A_3 port FC-VI b |
25 | 19 | controller_A_3 port FC-VI d | |||
28 | 22 | controller_A_4 port FC-VI b | |||
29 | 23 | controller_A_4 port FC-VI d | |||
FC_switch_B_2 | B | 8 | 24 | 18 | controller_B_3 port FC-VI b |
25 | 19 | controller_B_3 port FC-VI d | |||
28 | 22 | controller_B_4 port FC-VI b | |||
29 | 23 | controller_B_4 port FC-VI d |
Zone in Fabric_2 | Member ports |
---|---|
QOSH2_MC2_FAB_2_FCVI (B6510) | 6,24;6,25;6,28;6,29;8,24;8,25;8,28;8,29 |
Fabric | Zone name | Member ports |
---|---|---|
FC_switch_A_1 and FC_switch_B_1 | QOSH1_MC1_FAB_1_FCVI | 5,0;5,1;5,4;5,5;7,0;7,1;7,4;7,5 |
QOSH2_MC1_FAB_1_FCVI ( B6510) | 5,24;5,25;5,28;5,29;7,24;7,25;7,28;7,29 | |
FC_switch_A_2 and FC_switch_B_2 | QOSH1_MC1_FAB_2_FCVI | 6,0;6,1;6,4;6,5;8,0;8,1;8,4;8,5 |
QOSH2_MC1_FAB_2_FCVI (B6510) | 6,24;6,25;6,28;6,29;8,24;8,25;8,28;8,29 |