Zoning for FibreBridge 7600N bridges using one FC port
If you are using FibreBridge 7600N bridges using only one of the two FC ports, you need to create storage zones for the bridge ports. You should understand the zones and associated ports before you configure the zones.
The examples show zoning for DR group 1 only. If your configuration includes a second DR group, configure the zoning for the second DR group in the same manner, using the corresponding ports of the controllers and bridges.
Required zones
You must configure one zone for each of the FC-to-SAS bridge FC ports that allows traffic between initiators on each controller module and that FC-to-SAS bridge.
Eight HBA initiator ports (two connections for each controller)
One port connecting to an FC-to-SAS bridge FC port
The storage zones use standard zoning.
The examples show two pairs of bridges connecting two stack groups at each site. Because each bridge uses one FC port, there are a total of four storage zones per fabric (eight in total).
Bridge naming
This portion of the name... | Identifies the... | Possible values... |
---|---|---|
site | Site on which the bridge pair physically resides. | A or B |
stack group | Number of the stack group to which the bridge pair connects.
| 1, 2, etc. |
location in pair | Bridge within the bridge pair. A pair of bridges connect to a specific stack group. | a or b |
bridge_A_1a
bridge_A_1b
bridge_B_1a
bridge_B_1b
DR Group 1 - Stack 1 at Site_A
DrGroup 1 : MC1_INIT_GRP_1_SITE_A_STK_GRP_1_TOP_FC1 | ||||
---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... |
Lenovo B6505 FC SAN switch, B6510, DB620S, or DB610S switch | ||||
FC_switch_A_1 | A | 5 | 2 | controller_A_1 port 0a |
3 | controller_A_1 port 0c | |||
6 | controller_A_2 port 0a | |||
7 | controller_A_2 port 0c | |||
8 | bridge_A_1a FC1 | |||
FC_switch_B_1 | B | 7 | 2 | controller_B_1 port 0a |
3 | controller_B_1 port 0c | |||
6 | controller_B_2 port 0a | |||
7 | controller_B_2 port 0c |
Zone in Fabric_1 | Member ports |
---|---|
MC1_INIT_GRP_1_SITE_A_STK_GRP_1_TOP_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;5,8 |
DrGroup 1 : MC1_INIT_GRP_1_SITE_A_STK_GRP_1_BOT_FC1 | ||||
---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... |
Lenovo B6505 FC SAN switch, B6510, DB620S, or DB610S switch | ||||
FC_switch_A_1 | A | 6 | 2 | controller_A_1 port 0b |
3 | controller_A_1 port 0d | |||
6 | controller_A_2 port 0b | |||
7 | controller_A_2 port 0d | |||
8 | bridge_A_1b FC1 | |||
FC_switch_B_1 | B | 8 | 2 | controller_B_1 port 0b |
3 | controller_B_1 port 0d | |||
6 | controller_B_2 port 0b | |||
7 | controller_B_2 port 0d |
Zone in Fabric_2 | Member ports |
---|---|
MC1_INIT_GRP_1_SITE_A_STK_GRP_1_BOT_FC1 | 6,2;6,3;6,6;6,7;8,2;8,3;8,6;8,7;6,8 |
DR Group 1 - Stack 2 at Site_A
DrGroup 1 : MC1_INIT_GRP_1_SITE_A_STK_GRP_2_TOP_FC1 | ||||
---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... |
Lenovo B6505 FC SAN switch, B6510, DB620S, or DB610S switch | ||||
FC_switch_A_1 | A | 5 | 2 | controller_A_1 port 0a |
3 | controller_A_1 port 0c | |||
6 | controller_A_2 port 0a | |||
7 | controller_A_2 port 0c | |||
9 | bridge_A_2a FC1 | |||
FC_switch_B_1 | B | 7 | 2 | controller_B_1 port 0a |
3 | controller_B_1 port 0c | |||
6 | controller_B_2 port 0a | |||
7 | controller_B_2 port 0c |
Zone in Fabric_1 | Member ports |
---|---|
MC1_INIT_GRP_1_SITE_A_STK_GRP_2_TOP_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;5,9 |
DrGroup 1 : MC1_INIT_GRP_1_SITE_A_STK_GRP_2_BOT_FC1 | ||||
---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... |
Lenovo B6505 FC SAN switch, B6510, DB620S, or DB610S switch | ||||
FC_switch_A_1 | A | 6 | 2 | controller_A_1 port 0b |
3 | controller_A_1 port 0d | |||
6 | controller_A_2 port 0b | |||
7 | controller_A_2 port 0d | |||
9 | bridge_A_2b FC1 | |||
FC_switch_B_1 | B | 8 | 2 | controller_B_1 port 0b |
3 | controller_B_1 port 0d | |||
6 | controller_B_2 port 0b | |||
7 | controller_B_2 port 0d |
Zone in Fabric_2 | Member ports |
---|---|
MC1_INIT_GRP_1_SITE_A_STK_GRP_2_BOT_FC1 | 6,2;6,3;6,6;6,7;8,2;8,3;8,6;8,7;6,9 |
DR Group 1 - Stack 1 at Site_B
DrGroup 1 : MC1_INIT_GRP_1_SITE_B_STK_GRP_1_TOP_FC1 | ||||
---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... |
Lenovo B6505 FC SAN switch, B6510, DB620S, or DB610S switch | ||||
FC_switch_A_1 | A | 5 | 2 | controller_A_1 port 0a |
3 | controller_A_1 port 0c | |||
6 | controller_A_2 port 0a | |||
7 | controller_A_2 port 0c | |||
FC_switch_B_1 | B | 7 | 2 | controller_B_1 port 0a |
3 | controller_B_1 port 0c | |||
6 | controller_B_2 port 0a | |||
7 | controller_B_2 port 0c | |||
8 | bridge_B_1a FC1 |
Zone in Fabric_1 | Member ports |
---|---|
MC1_INIT_GRP_1_SITE_B_STK_GRP_1_TOP_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;7,8 |
DrGroup 1 : MC1_INIT_GRP_1_SITE_B_STK_GRP_1_BOT_FC1 | ||||
---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... |
Lenovo B6505 FC SAN switch, B6510, DB620S, or DB610S switch | ||||
FC_switch_A_1 | A | 6 | 2 | controller_A_1 port 0b |
3 | controller_A_1 port 0d | |||
6 | controller_A_2 port 0b | |||
7 | controller_A_2 port 0d | |||
FC_switch_B_1 | B | 8 | 2 | controller_B_1 port 0b |
3 | controller_B_1 port 0d | |||
6 | controller_B_2 port 0b | |||
7 | controller_B_2 port 0d | |||
8 | bridge_B_1b FC1 |
Zone in Fabric_2 | Member ports |
---|---|
MC1_INIT_GRP_1_SITE_B_STK_GRP_1_BOT_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;8,8 |
DR Group 1 - Stack 2 at Site_B
DrGroup 1 : MC1_INIT_GRP_1_SITE_B_STK_GRP_2_TOP_FC1 | ||||
---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... |
Lenovo B6505 FC SAN switch, B6510, DB620S, or DB610S switch | ||||
FC_switch_A_1 | A | 5 | 2 | controller_A_1 port 0a |
3 | controller_A_1 port 0c | |||
6 | controller_A_2 port 0a | |||
7 | controller_A_2 port 0c | |||
FC_switch_B_1 | B | 7 | 2 | controller_B_1 port 0a |
3 | controller_B_1 port 0c | |||
6 | controller_B_2 port 0a | |||
7 | controller_B_2 port 0c | |||
9 | bridge_b_2a FC1 |
Zone in Fabric_1 | Member ports |
---|---|
MC1_INIT_GRP_1_SITE_b_STK_GRP_2_TOP_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;7,9 |
DrGroup 1 : MC1_INIT_GRP_1_SITE_B_STK_GRP_2_BOT_FC1 | ||||
---|---|---|---|---|
FC switch | Site | Switch domain | Switch port | Connects to... |
Lenovo B6505 FC SAN switch, B6510, DB620S, or DB610S switch | ||||
FC_switch_A_1 | A | 6 | 2 | controller_A_1 port 0b |
3 | controller_A_1 port 0d | |||
6 | controller_A_2 port 0b | |||
7 | controller_A_2 port 0d | |||
FC_switch_B_1 | B | 8 | 2 | controller_B_1 port 0b |
3 | controller_B_1 port 0d | |||
6 | controller_B_2 port 0b | |||
7 | controller_B_2 port 0d | |||
9 | bridge_B_1b FC1 |
Zone in Fabric_2 | Member ports |
---|---|
MC1_INIT_GRP_1_SITE_B_STK_GRP_2_BOT_FC1 | 6,2;6,3;6,6;6,7;8,2;8,3;8,6;8,7;8,9 |
Summary of storage zones
Fabric | Zone name | Member ports |
---|---|---|
FC_switch_A_1 and FC_switch_B_1 | MC1_INIT_GRP_1_SITE_A_STK_GRP_1_TOP_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;5,8 |
MC1_INIT_GRP_1_SITE_A_STK_GRP_2_TOP_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;5,9 | |
MC1_INIT_GRP_1_SITE_B_STK_GRP_1_TOP_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;7,8 | |
MC1_INIT_GRP_1_SITE_B_STK_GRP_2_TOP_FC1 | 5,2;5,3;5,6;5,7;7,2;7,3;7,6;7,7;7,9 | |
FC_switch_A_2 and FC_switch_B_2 | MC1_INIT_GRP_1_SITE_A_STK_GRP_1_BOT_FC1 | 6,2;6,3;6,6;6,7;8,2;8,3;8,6;8,7;6,8 |
MC1_INIT_GRP_1_SITE_A_STK_GRP_2_BOT_FC1 | 6,2;6,3;6,6;6,7;8,2;8,3;8,6;8,7;6,9 | |
MC1_INIT_GRP_1_SITE_B_STK_GRP_1_BOT_FC1 | 6,2;6,3;6,6;6,7;8,2;8,3;8,6;8,7;8,8 | |
MC1_INIT_GRP_1_SITE_B_STK_GRP_2_BOT_FC1 | 6,2;6,3;6,6;6,7;8,2;8,3;8,6;8,7;8,9 |