Skip to main content

SC750 V4 installed – Electrical input specifications

Summary of the electrical input specifications for N1380 enclosure installed with SC750 V4 trays. Depending on the model, some features might not be available, or some specifications might not apply.

Electrical input
SC750 V4 tray installed in N1380 enclosure
Supports up to four 15000W Power Conversion Stations (PCS):
  • The enclosure must be installed with at least three PCS.

  • Input voltage: 380 – 480 Vac (Acbel DWC PCS)

  • Redundancy: work as N+1 with OVS and N+N with OVS (OVS: oversubscription)

  • Resetting SMM3 to factory defaults will cause the PCS redundancy mode to return to the default N+1 mode. If needed, re-configure PCS redundancy mode as the original or as loading required via SMM3.

CAUTION

Power Conversion Stations and redundant Power Conversion Stations in the enclosure must be with the same brand, power rating, wattage or efficiency level.

Mixing PSUs manufactured by different vendors is not supported.

Note
Refer to SMM3 User Guide for more details of solution power status.