FQXSPCA0046J : DIMM [DIMMId] temperature going high (upper non-critical) has asserted.
DIMM [DIMMId] temperature going high (upper non-critical) has asserted.
This message is for the use case when an implementation has detected an Upper Non-critical sensor going high has asserted.
Severity
Warning
Alert Category
Warning - Temperature
Serviceable
Yes
SNMP Trap ID
12
Automatically Notify Support
No
User Action
Complete the following steps until the problem is solved:
- Check the XCC event log for any fan or cooling related issues and address them first.
- Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are correctly installed and are in place.
- Make sure that the room temperature is within operating specifications.
- Upgrade all system and chassis (if applicable) firmware to the latest level.NoteIf the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before the update.
- If the problem persists, collect service data log.
- Contact Lenovo Support.
피드백 보내기