FQXSFMA0056M : An uncorrected recoverable memory error has been detected on DIMM [arg1] at address [arg2].[arg3]
An uncorrected recoverable memory error has been detected on DIMM [arg1] at address [arg2].[arg3]
Parameters
[arg1] DIMM Silk Label, 1-based
[arg2] Address of the system where error occurred
[arg3] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
Severity
Error
User Action
- Power off the system and remove A/C power.
- Reseat the failing DIMM identified by LightPath and/or event log entry
- Restore A/C power and power on the system.
- Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error.
- Run advance memory test using the XClarity Provisioning Manager. Click Diagnostics > Run Diagnostics > Memory Test > Advanced Memory Test to repair the DIMM.
- If the problem persists, collect Service Data logs and contact Lenovo Support.