FQXSPPW0035M : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted.
Severity
Error
Alert Category
Critical - Voltage
Serviceable
Yes
SNMP Trap ID
1
Automatically Notify Support
Yes
User Action
Complete the following steps:
- Reseat/reinstall CMOS battery.
- If problem still exist, (trained technician only) reseat the identified compute node by XCC or SMM2 Web GUI
- If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only) replace the system board.
- If the specified sensor is Planar 12V, ensure PIB board is installed correcly and check the XClarity Controller event log for power-supply-related issues, and resolve those issues.
- If the problem remains, (trained technician only) replace the PIB board or system board.
Give documentation feedback