Skip to main content

FQXSPPW0047M : Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

Numeric sensor [NumericSensorElementName] going high (upper critical) has asserted.

This message is for the use case when an implementation has detected an Upper Critical sensor going high has asserted.

Severity

Error

Alert Category

Critical - Voltage

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0494

SNMP Trap ID

1

Automatically Notify Support

Yes

User Action

Complete the following steps:

  1. Reseat/reinstall CMOS battery.
  2. If problem still exist, (trained technician only) reseat the identified compute node by XCC or SMM2 Web GUI
  3. If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only) replace the system board.
  4. If the specified sensor is Planar 12V, ensure PIB board is installed correcly and check the XClarity Controller event log for power-supply-related issues, and resolve those issues.