FQXSPMA0007L : Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
Scrub Failure for [PhysicalMemoryElementName] on Subsystem [MemoryElementName].
This message is for the use case when an implementation has detected a Memory Scrub failure.
Severity
Error
Alert Category
Critical - Memory
Serviceable
Yes
SNMP Trap ID
41
Automatically Notify Support
Yes
User Action
Complete the following steps:
- Ensure one or more DIMMs are installed in the node.
- Resolve existing memory errors if they are present.
- If no memory fault is recorded in the logs, verify that all DIMM connectors are enabled using the Setup utility or the OneCLI utility.
- Reseat all DIMMs ensuring that DIMMs are installed in the correct population sequence, according to the service information for this product.
- Clear CMOS memory on system board. Note that all firmware settings will revert to the defaults.
- Reflash UEFI firmware.
- If problem persists, collect Service Data log.
- Contact Lenovo Support.
Give documentation feedback