Skip to main content

Fan problems

See this section to resolve issues related the to fans.

Abnormally high RPM (revolutions per minute)

Complete the following steps until the problem is solved.
  1. With air flow sensor board installed, SE360 V2 BMC supports dust filter measurement feature to check the status of the rear dust filter. Log in to Lenovo XClarity Controller web interface, and go to Utilization > Fan Speed (RPM) > Dust Filter Measurement to take the measurement by selecting Run immediately (once), or by setting a regular schedule. When taking the measurement, the fans will operate at full fan speed for about 30 seconds. Make sure the high RPM is not caused by dust filter measurement.

  2. Check to see if the system inlet perforation or heatsinks are clogged.

  3. Make sure that all air baffles are correctly installed in the server.

  4. Check the thermal grease on the processor, and make sure it's not contaminated.