Power on and power off problems
Use this information to resolve issues when powering on or powering off the server.
Server does not power on
Check the event log for any events related to the server not powering on.
Check for any LEDs that are flashing amber.
Check the power LED on the system board (system board assembly).
Check if the power status led at the rear of the server is lit on.
AC cycle the system.
Remove the CMOS battery for at least ten seconds, then, reinstall the CMOS battery.
Try to power on the system by IPMI command through XCC or by the power button.
Implement the minimum configuration (see Technical specifications).
Reseat all power source, power module board (PMB), PIB module and all the cables that connect PMB and PIB module; then, check if the power status LED at the rear of the server is lit on.
If the issue cannot be resolved by above actions, call service to review the issue symptom and see whether the system board (system board assembly) replacement is necessary.