The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.
Table 1. Specifications
Specification
Description
Dimension
2U server
300mm chassis
Depth:
Without bezel: 298.8 mm (11.76 inches)
With bezel: 407.3 mm (16.04 inches)
Height: 86.5 mm (3.41 inches)
Width:
Without rack latches: 444.6 mm (17.50 inches)
With rack latches: 480.5 mm (18.92 inches)
360mm chassis
Depth:
Without bezel: 358.8 mm (14.13 inches)
With bezel: 467.3 mm (18.40 inches)
Height: 86.5 mm (3.41 inches)
Width:
Without rack latches: 444.6 mm (17.50 inches)
With rack latches: 480.5 mm (18.92 inches)
Weight
(Varies with configuration)
Maximum:
300mm chassis: 14.84 kg (32.71 lbs)
360mm chassis: 17.45 kg (38.47 lbs)
Processor
(Varies with configuration)
Supports multi-core Intel Xeon processors, with integrated memory controller and Intel Mesh UPI (Ultra Path Interconnect) topology.
One processor socket
Designed for LGA 4189 sockets
Scalable up to 36 cores
Supports 6 UPI links at 10.4 GT/s
Heat sink:
1U heat sink supports processors with wattage up to 165 watt.
2U heat sink supports processors with wattage up to 205 watt.
Intel Virtual RAID On CPU (VROC) for non-SED SATA/NVMe drives
Intel Volume Management Device (VMD) for non-SED NVMe drives
Network
One of the following OCP 3.0 Ethernet adapters
Intel I350-T4 PCIe 1GbE 4-port RJ45
Intel X710-T2L 10GBASE-T 2-port
Intel E810-DA2 10/25GbE SFP28 2-port
Mellanox ConnectX-6 Lx 10/25GbE SFP28 2-port
Expansion slots
(Varies with configuration)
Up to seven slots:
Slot 1 to 2: M.2 Drive 0 and 1
Slot 3 to 4 (Riser 2):
Supports the following:
Single-width PCI Express 4.0 x8/x16 (Slot 3, 4)
Single-width PCI Express 4.0 x16/x16 (Slot 3, 4)
Single/double-width PCI Express 4.0 x16 (Slot 4)
Two 2.5-inch hot-swap SAS/SATA/NVMe drives (Drive 4, 5)
Slot 5 to 6 (Riser 1):
Supports the following:
Single-width PCI Express 4.0 x16/x8 (Slot 5, 6)
Single-width PCI Express 4.0 x16/x16 (Slot 5, 6)
Single/double-width PCI Express 4.0 x16 (Slot 5)
Note
RAID adapter must be installed in Slot 6.
Slot 7: OCP 3.0 Ethernet adapter
Integrated functions
Lenovo XClarity Controller (XCC), which provides service processor control and monitoring functions, video controller, and remote keyboard, video, mouse, and remote drive capabilities.
One XCC system management port on the front to connect to a systems-management network. This connector is dedicated to the Lenovo XClarity Controller functions and runs at 1 GB speed.
Two universal serial bus (USB) 3.1 ports on the front
Fans
Six (60 mm x 60 mm x 56 mm) trayless system fans with N+1 redundancy support
Operating System
Supported and certified operating systems include:
This server supports up to two units of CFF V4 (reverse fan) power supplies. N+1 redundancy is supported when two units are installed. Following is the list of supported types:
1100-watt Platinum, input power 100-240 Vac
1100-watt Titanium, input power 100-240 Vac
1800-watt Platinum, input power 200-240 Vac
1100-watt -48V dc
CAUTION
240 V dc input (input range: 180-300 V dc) is supported in Chinese Mainland ONLY.
Power supply with 240 V dc input cannot support hot-plugging power cord function. Before removing the power supply with dc input, please turn off server or disconnect dc power sources at the breaker panel or by turning off the power source. Then, remove the power cord.
Minimal configuration for debugging
One processor
One DRAM DIMM in slot 2
One power supply
Two 15mm trayless drives with RAID (If OS is needed for debugging)
Six system fans (Fan 1 to 6)
Ambient temperature management
Adjust ambient temperature when specific components are installed:
Keep the ambient temperature to 35°C or lower when:
One or more 2.5-inch U.3 7400 PRO 3.84 TB Read Intensive NVMe PCIe 4.0 x4 trayless drives are installed
One or more 2.5-inch U.3 7450 PRO 3.84 TB Read Intensive NVMe PCIe 4.0 x4 trayless drives are installed
Keep the ambient temperature to 40°C or lower when:
NVIDIA A40 or L40 GPU is installed
One or more Persistent memory modules are installed
One of the following 2.5-inch drives is installed in Riser 2:
These sound levels were measured in controlled acoustical environments according to procedures specified by ISO7779 and are reported in accordance with ISO 9296.
The declared acoustic sound levels are based on the following configurations, which may change depending on configuration/conditions
Minimal: 300mm Chassis, 1x 185W/32cores CPU, 8x 16GB RDIMM, 4x 960G SATA SSD, 2x M.2 5300 SATA 480GB, 2x Intel E810-DA2, 2 x 1100W PSU
ThinkEdge SE450 complies with ASHARE Class A3 specifications. Depending on the hardware configuration, some models comply with ASHARE Class A4 specifications. System performance may be impacted when operating temperature is outside AHSARE A3 specification.
Air temperature:
Operating
ASHARE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
ASHARE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
ASHARE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
NEBS Level 3: 5%~85% RH, Non-condensing
Particulate contamination
Attention
Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
Note
The server is designed for standard data center environment and recommended to be placed in industrial data center.
SE450 supports use of a dust filter that is installed inside the security bezel. The dust filler has a Minimum Efficiency Rating Value (MERV) of 2, per ASHRAE Standard 52.2-2017.
Shock and vibration specifications The following information is a summary of the shock and vibration specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.
Particulate contamination Attention: Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the device that is described in this document.
2 Short-term conditions: period of no more than 96 consecutive hours and a total of not more than 15 days in 1 year. (This refers to a total of 360 hours in any given year, but no more than 15 occurrences during that 1- year period.)