Skip to main content

Server models with sixteen 2.5-inch drives

Use this section to understand the cable routing for server models with sixteen 2.5-inch drives.

Server model: sixteen 2.5-inch SAS/SATA drives, two 8i RAID/HBA adapters

Note
The following illustrations are based on the scenario that one RAID/HBA adapter is installed in PCIe slot 4 on the system board and the other one is installed in PCIe slot 1 on riser 1. If there is a serial port module installed in PCIe slot 4, the RAID/HBA adapters will be installed in PCIe slot 1 and PCIe slot 2 on riser 1. In both scenarios, the cable connections are the same.
Figure 1. Cable routing for server models with sixteen 2.5-inch SAS/SATA drives and two 8i RAID/HBA adapters
Cable routing for server models with sixteen 2.5-inch SAS/SATA drives and two 8i RAID/HBA adapters

CableFromTo
1 Power cable for backplane 1Power connector on backplane 1Backplane power connector 1 on the system board
2 SAS signal cable for backplane 1*SAS 0 and SAS 1 connectors on backplane 1
HBA/RAID adapter installed in PCIe slot 4:
  • Gen 3: C0C1

  • Gen 4: C0

3 Power cable for backplane 2Power connector on backplane 2Backplane power connector 2 on the system board
4 SAS signal cable for backplane 2*SAS 0 and SAS 1 connectors on backplane 2
HBA/RAID adapter installed in PCIe slot 1:
  • Gen 3: C0C1

  • Gen 4: C0

Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).

Server model: sixteen 2.5-inch SAS/SATA drives, one 16i RAID/HBA adapter

Note
The following illustrations are based on the scenario that the RAID/HBA adapter is installed in PCIe slot 4 on the system board. If there is a serial port module installed in PCIe slot 4, the RAID/HBA adapter will be installed in PCIe slot 1 on riser 1. In both scenarios, the cable connections are the same.
Figure 2. Cable routing for server models with sixteen 2.5-inch SAS/SATA drives and one 16i RAID/HBA adapter
Cable routing for server models with sixteen 2.5-inch SAS/SATA drives and one 16i RAID/HBA adapter

CableFromTo
1 Power cable for backplane 1Power connector on backplane 1Backplane power connector 1 on the system board
2 SAS signal cable for backplane 1*SAS 0 and SAS 1 connectors on backplane 1
HBA/RAID adapter:
  • Gen 3: C0C1

  • Gen 4: C0

3 Power cable for backplane 2Power connector on backplane 2Backplane power connector 2 on the system board
4 SAS signal cable for backplane 2*SAS 0 and SAS 1 connectors on backplane 2
HBA/RAID adapter:
  • Gen 3: C2C3

  • Gen 4: C1

Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).

Server model: twelve 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, one 16i RAID/HBA adapter

Note

The following illustrations are based on the scenario that the RAID/HBA adapter is installed in PCIe slot 4 on the system board. If there is a serial port module installed in PCIe slot 4, the RAID/HBA adapter will be installed in PCIe slot 1 on riser 1. In both scenarios, the cable connections are the same.

Figure 3. Cable routing for server models with twelve 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, and one 16i RAID/HBA adapter
Cable routing for server models with twelve 2.5-inch SAS/SATA drives, four 2.5-inch SAS/SATA/NVMe drives, and one 16i RAID/HBA adapter

CableFromTo
1 Power cable for backplane 1Power connector on backplane 1Backplane power connector 1 on the system board
2 SAS signal cable for backplane 1*SAS 0 and SAS 1 connectors on backplane 1
HBA/RAID adapter:
  • Gen 3: C0C1

  • Gen 4: C0

3 NVMe signal cable for backplane 1NVMe 0, NVMe 1, NVMe 2, and NVMe 3 connectors on backplane 1NVMe 0–1 and NVMe 2–3 connectors on the system board
4 Power cable for backplane 2Power connector on backplane 2Backplane power connector 2 on the system board
5 SAS signal cable for backplane 2*SAS 0 and SAS 1 connectors on backplane 2
HBA/RAID adapter:
  • Gen 3: C2C3

  • Gen 4: C1

Note
*When Gen 4 HBA/RAID adapter is installed, ensure you use Gen 4 SAS signal cable (ThinkSystem SR550/SR590/SR650 2.5" SAS/SATA/AnyBay 8-Bay X40 RAID Cable Kit).