Server models with twelve 3.5-inch drives
Use this section to understand the cable routing for server models with twelve 3.5-inch drives.
Server model: twelve 3.5-inch SAS/SATA drives, one 16i RAID/HBA adapter
PCIe slot 1 on riser 1 if there is no rear hot-swap drive assembly installed
PCIe slot 6 on riser 2 if there is a rear hot-swap drive assembly installed
Cable | From | To |
---|---|---|
1 Power cable | Power connector 1 on the backplane | Backplane power connector 1 on the system board |
2 Power cable | Power connector 2 on the backplane | Backplane power connector 2 on the system board |
3 SAS signal cable* | SAS 0, SAS 1, and SAS 2 connectors on the backplane | HBA/RAID adapter:
|
Server model: eight 3.5-inch SAS/SATA drives, four 3.5-inch NVMe drives, one 8i RAID/HBA adapter
The following illustration is based on the scenario that the RAID/HBA adapter is installed in PCIe slot 4 on the system board. If there is a serial port module installed in PCIe slot 4, the RAID/HBA adapter will be installed in PCIe slot 1 on riser 1. For both scenarios, the cable connections are the same.
Cable | From | To |
---|---|---|
1 Power cable | Power connector 1 on the backplane | Backplane power connector 1 on the system board |
2 Power cable | Power connector 2 on the backplane | Backplane power connector 2 on the system board |
3 SAS signal cable* | SAS 0 and SAS 1 connectors on the backplane | HBA/RAID adapter:
|
4 NVMe signal cable | NVMe 0, NVMe 1, NVMe 2, and NVMe 3 connectors on the backplane | NVMe 0–1 and 2–3 connectors on the system board |
Server model: eight 3.5-inch SAS/SATA drives, four 3.5-inch SAS/SATA/NVMe drives, one 16i RAID/HBA adapter
PCIe slot 1 on riser 1 if there is no rear hot-swap drive assembly installed
PCIe slot 6 on riser 2 if there is a rear hot-swap drive assembly installed
Cable | From | To |
---|---|---|
1 Power cable | Power connector 1 on the backplane | Backplane power connector 1 on the system board |
2 Power cable | Power connector 2 on the backplane | Backplane power connector 2 on the system board |
3 SAS signal cable* | SAS 0, SAS 1, and SAS 2 connectors on the backplane | HBA/RAID adapter:
|
4 NVMe signal cable | NVMe 0, NVMe 1, NVMe 2, and NVMe 3 connectors on the backplane | NVMe 0–1 and 2–3 connectors on the system board |