FQXSFMA0002M : An uncorrectable memory error has been detected on DIMM [arg1] at address [arg2]. [arg3]
An uncorrectable memory error has been detected on DIMM [arg1] at address [arg2]. [arg3]
Parameters
[arg1] DIMM Silk Label, 1-based
[arg2] Address of the system where error occurred
[arg3] DIMM identifier consists of S/N, FRU and UDI, e.g. "739E68ED-VC10 FRU 0123456"
Severity
Error
User Action
Complete the following steps:
- Check Lenovo Support site for an applicable service bulletin or firmware update that applies to this memory error.
- Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event denoting detected change in DIMM population that could be related to this problem.)
- Swap the affected DIMM to another known good slot and verify whether the issue still be observed or not.
- If the problem persists, collect Service Data logs and contact Lenovo Support.NoteThe solution for this error may involve a system board replacement. If TPM encryption has been enabled, back up TPM Encryption Recovery Key.