Skip to main content

Parts list

Identify each of the components that is available for your server with the parts list.

For more information about ordering parts:
  1. Go to Lenovo Data Center Support, and enter the model name or machine type of your server in the search bar to navigate to the support page.

  2. Click Parts.

  3. Enter the serial number to view a listing of parts for your server.

It is highly recommended that you check the power summary data for your server using Lenovo Capacity Planner before purchasing any new parts.

Note
Depending on the model, your server might look slightly different from the illustration.
Figure 1. Server components

The parts listed in the following table are identified as one of the following:
  • T1: Tier 1 customer replaceable unit (CRU). Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request with no service agreement, you will be charged for the installation.

  • T2: Tier 2 customer replaceable unit (CRU). You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.

  • FRU: Field replaceable unit (FRU). FRUs must be installed only by trained service technicians.

  • C: Consumable and Structural parts. Purchase and replacement of consumable and structural parts is your responsibility. If Lenovo acquires or installs a structural component at your request, you will be charged for the service.

DescriptionTypeDescriptionType
1 Top coverT12 Air baffleT1
3 Riser bracket (low profile, LP)T14 Riser bracket (low profile-full height, LP-FH)T1
5 Riser bracket (full height, FH)T16 Riser bracket (full height, FH)T1
7 Rear riser bracket (full height, FH)T18 Front riser cagesT1
9 Riser 5–4 cardT210 Riser 2–1 cardT2
11 Riser 2–2 cardT112 Riser 3 cardT1
13 Riser 1 cardT114 2.5-inch driveT1
15 Rear OCP interposer cardT116 Rear M.2 drive assemblyT2
17 Rear M.2 adapterT118 Rear M.2 adapter trayT1
19 Front OCP interposer cardT220 Rear M.2 cageT1
21 10 x 2.5-inch front drive backplaneT222 4 x 2.5-inch front drive backplaneT2
23 Rear M.2 backplaneT224 2 x 2.5-inch rear drive backplaneT2
25 2 x 2.5-inch rear drive cageT126 Processor and heat sink module fillerC
27 2 x 2.5-inch rear drive cage air baffleT128 Intrusion switchT1
29 System fan-packT130 Memory moduleT1
31 Cold plate coverC32 Processor socket coverC
33 MicroSD cardT134 Security bezelC
35 M.2 driveT136 ChassisFRU
37 ProcessorFRU38 Internal M.2 backplaneT2
39 M.2 retainer clipT140 CMOS batteryC
41 Radiator holderT142 Heat sink PEEK nutT2
43 Standard heat sinkFRU44 Processor NeptuneTM Air Module (NeptAir)FRU
45 Performance heat sinkFRU46 Processor NeptuneTM Core Module (NeptCore)FRU
47 42U in-row hose kitFRU48 Bleeder kitFRU
49 ManifoldsFRU50 42U/48U in-rack connection hose (return side)FRU
51 42U in-rack connection hose (supply side)FRU52 48U in-rack connection hose (supply side)FRU
53 PCIe adapterT154 Processor boardFRU
55 System I/O boardFRU56 USB I/O boardT1
57 Power supply unitT158 OCP moduleT1
59 Power-supply-unit fillerC60 Front I/O module (1)T2
61 Front I/O module (2)T162 2.5-inch drive bay fillerC
63 Rack latch (right)T164 Rack latch (left)T1
65 External diagnostics handsetT166 Rear M.2 heat sink thermal padFRU