跳至主要内容

6 x 2.5'' SAS/SATA + 2 x 2.5'' NVMe + 2 x 2.5'' AnyBay backplane (liquid cooling)

Use this section to understand the AnyBay backplane cable routing for server model with ten 2.5-inch front drives for liquid cooling configuration.

Figure 1. Cable routing for 6 x 2.5'' SAS/SATA, 2 x 2.5'' NVMe, and 2 x 2.5'' AnyBay drives, and 1 x 16i/8i SFF RAID adapter (Gen 3/Gen 4)
Cable routing for 6 x 2.5'' SAS/SATA, 2 x 2.5'' NVMe, and 2 x 2.5'' AnyBay drives, and 1 x 16i/8i SFF RAID adapter (Gen 3/Gen 4)

Table 1. Mapping between RAID adapter, backplane, and processor board
FromToCable length
1 SAS 0 and SAS 1 connectors on backplane1
  • C0 and C1 connectors on Gen 3 RAID adapter

  • C0 connector on Gen 4 RAID adapter

  • Gen 3: 820/1020 mm

  • Gen 4: 900/1020 mm

2 Power connector on backplane2 Power connector 2A connector on processor board480 mm
3 NVMe 6-7 connector on backplane3 PCIe connector 4 on processor board550 mm
4 NVMe 8-9 connector on backplane4 PCIe connector 3 on processor board450 mm