Skip to main content

Fan board problems

Use this information to resolve issues related to the fan board.

To resolve the problem, do the following:
  1. Make sure that all the cables of the fan board are securely connected to the system board.

  2. Make sure that all fans are properly inserted into the fan board.

  3. Power on the server and then go to event log to check the fan status.

  4. If the fan module in any slots shows error, update the firmware.

  5. If the problem persists after firmware update, swap the defective fan with a good one.

  6. If the fan error follows with a specific fan module after swapping, replace the fan module.

  7. If the fan error follows with a specific fan slot after swapping, replace the fan board.

  8. If the fan error follows with a specific fan cable after swapping, replace the fan cable.