FQXSFSR0001M : [arg1] GPT corruption detected, DiskGUID: [arg2]
[arg1] GPT corruption detected, DiskGUID: [arg2]
Parameters
[arg1] GPT corruption location. "Primary"Only primary GPT partition table corruption. "Backup"Only backup GPT partition table corruption. "Both Primary and Backup"Both GPT partition tables corruption.
[arg2] Disk GUID.
Severity
Warning
User Action
Complete the following steps:
Remove all the external drive during POST to avoid that this event is triggered by mistake.
Check the XCC event log. If this event has a follow up recovery event log, it means that GTP corruption has been recovered successfully. Ignore this event message and do not perform the remaining steps.
Back up the data disk.
Press F1 Setup->System Settings->Recovery and RAS->Disk GPT Recovery and set the value to "Automatic".
Save the settings and restart the system.
Boot to F1 setup. The system will automatically try to recover the GPT during the POST.
Restart the system.
Re-format the LUN or disk and re-install the OS.
If the problem persists, collect Service Data logs and contact Lenovo Support.