FQXSFMA0032M : Intel Optane PMEM [arg1] has no remaining spares block.
Intel Optane PMEM [arg1] has no remaining spares block.
Severity
Error
User Action
Complete the following steps:
- Back up data.
- Check the current Intel Optane PMEM DIMM health status in one of the following ways:
- Run PMEM test under LXPM diagnostic. Look for “Percentage Remaining” of spare blocks.
- Check for “Remaining Life” of spare blocks on the XCC Web GUI.
- Check if the PMEM meets warranty terms.
- If the PMEM meets the warranty terms, contact Lenovo Support for PMEM replacement.
- If the PMEM does not meet the warranty terms, order a new comparable PMEM through an authorized Lenovo reseller.
- Collect Service log and contact Lenovo support to schedule PMEM replacement.(Note: Unless otherwise specified in other agreements or contract terms, parts beyond their warranty terms and/or parts that have reached their maximum usage limitations do not qualify for warranty service.)