The following information is a summary of the features and specifications of the server. Depending on the model, some features might not be available, or some specifications might not apply.
Table 1. Specifications.
Specification
Description
Dimension
4U server
Height: 175 mm (6.89 inches)
Width: 430 mm (16.93 inches)
Depth: 565.7 mm (22.27 inches)
Weight (depending on the configuration)
Maximum without package:
2.5-inch drive configuration: 21.98 kg (48.46 lb)
3.5-inch drive configuration: 24.28 kg (53.53 lb)
Minimum with package:
2.5-inch drive configuration: 17.96 kg (39.60 lb)
3.5-inch drive configuration: 20.04 kg (44.18 lb)
Processor
This server comes with one LGA 1200 socket that supports one of the following Intel® processors scalable up to eight cores:
Slot 1 and Slot 3 in the ST250 V2 are open-end design, which means that the slots can accept adapters with a longer edge connector than the physical length of the slot connector. For example, if a x8 adapter is installed in the x4 slot 3 of the server, half of the edge connector will not be connected to the slot. The adapter will still function, however performance will be impacted.
Input/Output (I/O) features
Front panel
One Lenovo XClarity Controller USB 2.0 connector
One USB 3.2 Gen 1 (5Gb) connector
Rear panel
One Video Graphics Array (VGA) connector
One serial connector
One Lenovo XClarity Controller network connector
Two Ethernet connectors (shared with Lenovo XClarity Controller network connector)
Two front system fans for drives (92 x 92 x 25 mm)
One rear system fan (120 x 120 x 25 mm)
Electrical input
Universal input:
Low range: 100 to 127 Vac
High range: 200 to 240 Vac
Input frequency range: 50 to 60 Hz
Note
ThinkSystem ST250 V2 only supports AC input power. Do not use 240 VDC input.
Power supply
Depending on your configuration, the server comes with one of the following power supply configurations:
One 250W or 300W single output fixed power supply
One 500W multi output fixed power supply
One or two 550W Platinum or 750W Titanium redundant power supplies
Acoustical noise emissions
The server has the following acoustic noise emissions declaration:
Sound power level (LWAd):
Idling: 4.3 Bel (Typical), 4.4 Bel (Max)
Operating: 4.3 Bel (Typical), 4.5 Bel (Max)
Sound pressure level (LpAm):
Idling: 27.4 dBA (Typical), 28.6 dBA (Max)
Operating: 27.6 dBA (Typical), 29.0 dBA (Max)
Note
These sound levels were measured in controlled acoustical environments according to procedures specified by ISO 7779 and are reported in accordance with ISO 9296, SPL is measured by bystander position(1m).
The declared acoustic sound levels are based on the following configurations, which may change depending on configuration/conditions, for example M.2 drive, Broadcom 57414 25Gb NIC, Broadcom 57416 10Gb NIC, T1000, etc.
Minimum configuration: 358.05 BTU per hour (105 watts)
Maximum configuration: 1029.82 BTU per hour (302 watts)
Ambient temperature management
Adjust ambient temperature when specific configuration is applied:
Eight 3.5-inch drives
When a 95W TDP CPU and a 95W performance heatsink are installed:
Keep ambient temperature to 35°C or lower. M.2 drives (up to 240GB) are supported in this configuration.
Keep ambient temperature to 30°C or lower when a 480GB M.2 drive is installed.
When an 80W (or lower) TDP CPU and an 80W heatsink are installed:
Keep ambient temperature to 35°C or lower. M.2 drives (up to 240GB) are supported in this configuration.
Keep ambient temperature to 30°C or lower when a 480GB M.2 drive is installed.
Sixteen 2.5-inch drives
When a 95W TDP CPU and a 95W performance heatsink are installed:
Keep ambient temperature to 35°C or lower. M.2 drives (up to 240GB) are supported in this configuration.
Keep ambient temperature to 30°C or lower when a 480GB M.2 drive is installed.
When an 80W (or lower) TDP CPU and an 80W heatsink are installed:
Keep ambient temperature to 35°C or lower. M.2 drives (up to 240GB) are supported in this configuration.
Keep ambient temperature to 30°C or lower when a 480GB M.2 drive is installed.
Eight 2.5-inch drives and four 3.5-inch drives
When an 80W TDP CPU and an 80W heatsink are installed:
Keep ambient temperature to 40°C or lower.
GPUs, M.2 drives, 10/25GbE Ethernet adapters, and redundant power supplies should not be installed in this configuration.
When a 70W (or lower) TDP CPU and an 80W heatsink are installed:
Keep ambient temperature to 45°C or lower.
GPUs, M.2 drives, 10/25GbE Ethernet adapters, and redundant power supplies should not be installed in this configuration.
Environment
The ThinkSystem ST250 V2 server complies with ASHRAE Class A2 specifications. Depending on the hardware configurations, some models comply with ASHRAE Class A3 and A4 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.
Air temperature:
Operating
ASHRAE Class A2: 10°C to 35°C (50°F to 95°F); the maximum ambient temperature decreases by 1°C for every 300 m (984 ft) increase in altitude above 900 m (2,953 ft).
ASHRAE Class A3: 5°C to 40°C (41°F to 104°F); the maximum ambient temperature decreases by 1°C for every 175 m (574 ft) increase in altitude above 900 m (2,953 ft).
ASHRAE Class A4: 5°C to 45°C (41°F to 113°F); the maximum ambient temperature decreases by 1°C for every 125 m (410 ft) increase in altitude above 900 m (2,953 ft).
Server off: 5°C to 45°C (41°F to 113°F)
Shipment/storage: -40°C to 60°C (-40°F to 140°F)
Maximum altitude: 3,050 m (10,000 ft)
Relative Humidity (non-condensing):
Operating
ASHRAE Class A2: 8% to 80%; maximum dew point: 21°C (70°F)
ASHRAE Class A3: 8% to 85%; maximum dew point: 24°C (75°F)
ASHRAE Class A4: 8% to 90%; maximum dew point: 24°C (75°F)
Shipment/storage: 8% to 90%
Particulate contamination
Attention
Airborne particulates and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the server. For information about the limits for particulates and gases, see Particulate contamination.
Operating systems
Supported and certified operating systems:
Microsoft Windows Server 2019, 2022
VMware ESXi 7.0 U3 or later versions
Red Hat Enterprise Linux 8.4 or later versions
SUSE Linux Enterprise Server 15 SP3 or later versions
One drive with RAID adapter and backplane or backplate (if OS is needed for debugging)
One system fan, one processor and heat sink fan, and one front system fan for drives
Particulate contamination Attention: Airborne particulates (including metal flakes or particles) and reactive gases acting alone or in combination with other environmental factors such as humidity or temperature might pose a risk to the device that is described in this document.