Skip to main content

Removing the fixed power supply

Use this information to remove the fixed power supply.

When you remove or install the fixed power supply, observe the following precautions.
Statement 8
Graphic illustrating Safety Statement 8
CAUTION
Never remove the cover on a power supply or any part that has the following label attached.
Hazardous voltage, current, and energy levels are present

Hazardous voltage, current, and energy levels are present inside any component that has this label attached. There are no serviceable parts inside these components. If you suspect a with one of these parts, contact a service technician.

Read the safety information in Safety and Installation guidelines.

If you are replacing a server component in the server, you need to slide the server out from the rack enclosure, turn off the server and peripheral devices, and disconnect the power cords and all external cables.

To remove the fixed power supply, complete the following steps.

  1. Remove the cover (see Removing the cover).
    Attention
    To ensure proper cooling and airflow, do not operate the server for more than 30 minutes with the cover removed.
  2. Disconnect the power-supply cables from the connectors on the system board and internal devices; then, disengage the cables from any retention-clips.
    Note
    Note the routing of all power-supply cables; you will route the power-supply cables the same way when you install the power supply.
    Figure 1. Fixed power supply removal
    Fixed power supply removal
  3. Remove the screw that holds the power supply to the rear of the chassis.
  4. Loosen the captive thumbscrew that secures the power supply to the chassis bottom.
  5. Lift the power supply out of the bay.

If you are instructed to return the server component or optional device, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.