Skip to main content

eXFlash DIMMs

This topic provides information about eXFlash DIMM installation and requirements.

The Lenovo System x3850 X6 and x3950 X6 server provides support for eXFlash™ DIMMs. You can use eXFlash DIMMs in unused DIMM slots for solid state drive storage on the server. For more information and notes about installing DIMMs, see Installing a memory module. eXFlash DIMMs are only supported in Independent memory mode. For more information about DIMM installation sequence for Independent memory mode, see Independent memory mode. The DIMM installation order for eXFlash DIMMs follows the independent mode (performance) installation order.

When you install an eXFlash DIMM, consider the following information:

  • RDIMMs must be installed in the server with eXFlash DIMMs. You cannot install all eXFlash DIMMs in the server.
  • RDIMMs must be installed first, then eXFlash DIMMs can be installed.
  • When you install eXFlash DIMMs, do not leave an empty DIMM slot between installed DIMMs.
  • For both the 4-socket and 8-socket configurations, one eXFlash DIMM can be installed in each DDR3 or DDR4 channel. A maximum of 8 eXFlash DIMMs can be installed in each compute book. A maximum of 32 eXFlash DIMMs can be installed in the server. In the 8-socket configuration of the server, the eXFlash DIMMs must be installed in the bottom node only.
  • Mixing of LRDIMMs and eXFlash DIMMs in the same server is not supported.
  • eXFlash DIMMs are supported in Independent memory mode only.
  • eXFlash DIMMs are not supported in Lockstep memory mode, memory mirroring, or memory rank sparing.
  • You can install any configuration of the supported eXFlash DIMMs (up to 32 eXFlash DIMMs) in the server.
  • The same level of firmware should be installed on all eXFlash DIMMs in the server.
  • When you install eXFlash DIMMs in the server, see Environment in the Server features and specifications section for the supported environment information for eXFlash DIMMs.
  • If you install eXFlash DIMMs on the Red Hat and SLES operating systems, keep in mind that the server supports only Red Hat Enterprise Linux version 6.5 or later and SUSE Linux Enterprise Server (SLES) version 11 SP3 or later operating systems. For more information about eXFlash DIMMs, go to the eXFlash DIMM Configuration and Support Requirements website.

The following table lists the supported eXFlash DIMMs specifications:

Table 1. eXFlash DDR3 DIMMs specifications.

Table with nine columns and headers that lists the supported eXFlash DDR3 DIMMs specifications

StorageSDRAM Equivalent CapacitySDRAM Equivalent DensitySDRAM Equivalent RanksSDRAM Equivalent OrganizationForm factorVoltageTypeBandwidth (MHz)
200 GB eXFlash DIMM8 GB4 Gb1R1024Mb x 4DDR3 Low profile1.35VRDIMM1600 MHz
400 GB eXFlash DIMM8 GB4 Gb1R1024Mb x4DDR3 Low profile1.35VRDIMM1600 MHz

When you install eXFlash DIMMs, follow the same installation order for the Independent memory mode with mirroring disabled as shown in the following table:

Table 2. DIMM population sequence for independent memory mode.

Three-column table with headers that lists the population sequence for independent memory mode

DIMM installation orderIndependent mode with memory mirroring disabledIndependent mode with memory mirroring enabled
1DIMM connector 9DIMM connectors 9 and 19
2DIMM connector 6DIMM connectors 6 and 16
3DIMM connector 1DIMM connectors 1 and 15
4DIMM connector 10DIMM connectors 10 and 24
5DIMM connector 15DIMM connectors 8 and 20
6DIMM connector 24DIMM connectors 5 and 17
7DIMM connector 19DIMM connectors 2 and 14
8DIMM connector 16DIMM connectors 11 and 23
9DIMM connector 8DIMM connectors 7 and 21
10DIMM connector 5DIMM connectors 4 and 18
11DIMM connector 2DIMM connectors 3 and 13
12DIMM connector 11DIMM connectors 12 and 22
13DIMM connector 14 
14DIMM connector 23 
15DIMM connector 20 
16DIMM connector 17 
17DIMM connector 7 
18DIMM connector 4 
19DIMM connector 3 
20DIMM connector 12 
21DIMM connector 13 
22DIMM connector 22 
23DIMM connector 21 
24DIMM connector 18