Configuring the power redundancy
To configure the power redundancy, use the information in this topic.
Note
- AMD servers do not support configuring the power policy function.
- When 2 power supply units are installed, the redundancy mode is set to Redundant (N+N). With this 2 Power supply units configuration, if one of the power supply units fail, AC lost or has been removed, it will report redundant lost event in XCC event log.
- When only 1 power supply unit is installed after shipping, the redundancy mode will be automatically set to Non-redundant mode.
- Zero Output Mode and Non-redundant are not available when CRPS PSUs are installed.
Available fields in the Power Redundancy section include the following:
- Redundant (N+N): There are two or more independent power sources that are capable of supplying power to the system simultaneously. This means that if one or more power sources fails, the other source(s) can continue to supply power to the system without any interruption. N+N redundancy provides a high level of fault tolerance and ensures that the system remains operational even in the event of multiple failures.
- Zero Output Mode: Once enabled under Redundant configuration, some PSUs will automatically enter into standby state under light load conditions. In this manner, the remaining PSU delivers the entire power load to increase efficiency.NoteThis option is not supported in SR680a V4 servers.
- Zero Output Mode: Once enabled under Redundant configuration, some PSUs will automatically enter into standby state under light load conditions. In this manner, the remaining PSU delivers the entire power load to increase efficiency.
- Redundant (N+1): There is one primary power source that is capable of supplying power to the system. Additionally, there is at least one backup power source that is available to take over if the primary source fails. The backup source is designed to provide enough power to keep the system running until the primary source can be repaired or replaced. N+1 redundancy provides a lower level of fault tolerance compared to N+N redundancy.NoteThis option is only supported in SR680a V4 servers.
- Non-redundant: In this mode, the server is not guaranteed to remain operational if a power supply is lost. The server will throttle if a power supply fails in an attempt to remain running.
Click Apply after making the configuration changes.
Give documentation feedback