1-1-2 Microprocessor register test failed. (Trained service technician only) Reseat the microprocessor. See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . Replace the following components one at a time, in the order shown, restarting the blade server each time:(Trained service technician only) Microprocessor - See Removing a microprocessor and heat sink and Installing a microprocessor and heat sink . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1-1-3 CMOS write/read test failed. Reseat the battery. See Removing the battery and Installing the battery . Replace the following components one at a time, in the order shown, restarting the blade server each time:Battery - See Removing the battery andInstalling the battery . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1-1-4 BIOS ROM checksum failed. Update the BIOS code. Go to http://www.ibm.com/systems/support/ . Reseat the DIMMs. See Removing a memory module and Installing a memory module . Replace the following components one at a time, in the order shown, restarting the blade server each time:DIMMs - See Removing a memory module and Installing a memory module . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 1-2-1 Programmable interval timer failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 1-2-2 DMA initialization failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 1-2-3 DMA page register write/read failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 1-2-4 RAM refresh verification failed. Reseat the DIMMs and the expansion unit if one is installed. Replace the following components one at a time, in the order shown, restarting the blade server each time:DIMMs - See Removing a memory module and Installing a memory module . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . Optional expansion unit (if one is installed) - See Removing an optional expansion unit and Installing an optional expansion unit . 1-3-1 First 64K RAM test failed. Reseat the DIMMs. See Removing a memory module and Installing a memory module . Replace the lowest-numbered pair of DIMMs with an identical known good pair of DIMMs; then, restart the blade server. If the beep code remains, go to Beep code descriptions . Return one DIMM at a time from the failed pair to its connector, restarting the blade server after each DIMM, to identify the failed DIMM. Replace the following components one at a time, in the order shown, restarting the blade server each time:DIMMs - See Removing a memory module and Installing a memory module . (Trained service technician only) System-board assembly - See Removing the system-board assembly andInstalling the system-board assembly . 1-3-2 First 64K RAM parity test failed. Reseat the DIMMs. See Removing a memory module and Installing a memory module . Replace the following components one at a time, in the order shown, restarting the blade server each time:DIMMs - See Removing a memory module and Installing a memory module . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 2-1-1 Secondary DMA register test failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly .. 2-1-2 Primary DMA register test failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 2-1-3 Primary interrupt mask register test failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 2-1-4 Secondary interrupt mask register test failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 2-2-2 Keyboard controller test failed. Check the function of the shared BladeCenter unit resources (see Solving shared BladeCenter resource problems ). (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 2-3-1 Screen initialization failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 2-4-4 Unsupported memory configuration. Check the DIMM error LEDs on the blade server. See Light path diagnostics LEDs for more information. Check the management-module event log for DIMM error messages. See Error logs . Replace noncompatible or failing DIMMs in the blade server. See Removing a memory module and Installing a memory module . 3-1-1 Timer tick interrupt failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 3-1-2 Interval timer channel 2 failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 3-1-4 Time-of-day clock failed. Reseat the battery. See Removing the battery and Installing the battery . Replace the following components one at a time, in the order shown, restarting the blade server each time:Battery - See Removing the battery and Installing the battery . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 3-2-1 Serial port failed. (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 3-2-2 Parallel port failed (Trained service technician only) Replace the system-board assembly. See Removing the system-board assembly and Installing the system-board assembly . 3-3-2 Critical SMBUS error occurred. Turn-off the blade server (see ) and reseat it in the BladeCenter unit. See Removing the blade server from the BladeCenter unit and Installing the blade server in a BladeCenter unit . Reseat the DIMMs. See Removing a memory module and Installing a memory module . Replace the following components one at a time, in the order shown, restarting the blade server each time:DIMMs - See Removing a memory module and Installing a memory module . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly . 3-3-3 No operational memory in system. In some memory configurations, the 3-3-3 beep code might sound during POST, followed by a blank monitor screen. If this occurs and the Boot Fail Count option in the Start Options of the Configuration/Setup Utility program is enabled, you must restart the blade server three times to reset the configuration settings to the default configuration (the memory connector or band of connectors enabled).
Install or reseat DIMMS and restart the blade server three times . See Removing a memory module and Installing a memory module . Replace the following components one at a time, in the order shown, restarting the blade server each time:DIMMs - See Removing a memory module and Installing a memory module . (Trained service technician only) System-board assembly - See Removing the system-board assembly and Installing the system-board assembly .